A New Dead-time Compensation Method Based on LMS Algorithm for PMSM
نویسندگان
چکیده
منابع مشابه
A New Method for Time-Delay Compensation in Control Systems
In this paper a new method is introduced and investigated for removing the destabilizing effects of time-delay parameter in control loops. The concept of the method is taken from the knowledge concerning the dynamic behaviour of irrational transfer functions (Ir-TF), which is discussed and investigated elswhere in frequency response domain and is explained briefly here. Ir-TFs, which are we...
متن کاملa new method for time-delay compensation in control systems
in this paper a new method is introduced and investigated for removing the destabilizing effects of time-delay parameter in control loops. the concept of the method is taken from the knowledge concerning the dynamic behaviour of irrational transfer functions (ir-tf), which is discussed and investigated elswhere in frequency response domain and is explained briefly here. ir-tfs, which are well c...
متن کاملOn-line dead-time compensation method based on time delay control
In this work, an on-line dead-time compensation method based on a time delay control for a pulse-modulation (PM) synchronous motor drive is presented. Disturbance voltages caused by the dead time are estimated on-line without any additional circuits nor off-line experimental measurements. The estimated disturbance voltages are fed back to the voltage reference as compensation. The proposed meth...
متن کاملDSP-based New On-line Dead Time Compensation Strategy of a PMSM Drive through Digital Signal Processing and Harmonic Component Extraction for a Robot Arm Application
Abstract DSP-based on-line dead time compensation strategy of a permanent magnet synchronous motor (PMSM) drive through a signal processing and harmonic extraction for a robot arm application is proposed. The proposed scheme is based on monitoring the fifth-order harmonic component through the signal processing and harmonic component extraction. The proposed scheme does not require a periodic i...
متن کاملA New Dead Time Compensation method for Stand - alone Inverter under Unbalanced Loads
phase stand-alone inverter is caused by unbalanced load and a dead time distorts inverter output voltage more unsymmetrically. When the inverter supplies unbalanced load, three phase output voltages include unbalanced odd harmonics but dq-axis voltages at synchronous reference frame have even harmonics with different magnitude each other. In this paper, a new compensation method is proposed to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2021
ISSN: 1742-6588,1742-6596
DOI: 10.1088/1742-6596/1754/1/012203