Microsisak – a New Device for Fast and Continuous Liquid-liquid Extractions on a Microliter Scale

The fast liquid-liquid extraction system SISAK-3 is based on small centrifuges with continuous feed and output of the liquid phases at flow rates ranging from 0.5 up to 3.0 ml/s [1]. With SISAK-3, the investigation of nuclides with half-lives down to about 1 s is possible. Recently, SISAK-3 combined with an on-line detection system for α-particles and SF-events [2] based on liquid scintillation...

متن کامل

New apparatus for liquid-liquid extraction, "emulsion flow" extractor.

A simple and low-cost apparatus for continuous and efficient liquid-liquid extraction, which does not need continual mechanical forces (stirring, shaking, etc.) other than solution sending, has newly been developed. This apparatus, named "emulsion flow" extractor, is composed of a column part where an emulsified state fluid flow (emulsion flow) is generated by spraying micrometer-sized droplets...

متن کامل

Graphene-based liquid crystal device.

Graphene is only one atom thick, optically transparent, chemically inert, and an excellent conductor. These properties seem to make this material an excellent candidate for applications in various photonic devices that require conducting but transparent thin films. In this letter, we demonstrate liquid crystal devices with electrodes made of graphene that show excellent performance with a high ...

متن کامل

Ionic liquid-based liquid-phase microextraction, a new sample enrichment procedure for liquid chromatography.

Room temperature ionic liquids (RTILs) were used as extraction solvent in liquid-phase microextraction (LPME) coupled with liquid chromatography. Using 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]) as extraction solvent, some parameters related to LPME of 4-nonylphenol (4-NP) and 4-tert-octylphenol (4-t-OP) were optimized. Although [C6MIM][PF6] can suspend a much larger volume ...

متن کامل

A method for bubble volume measurement under constant flow conditions in gas–liquid two-phase flow

Measuring the volume of a bubble, especially at its detachment, is a basic subject in gas-liquid two-phase flow research. A new indirect method for this measurement under constant flow conditions is presented. An electronic device is designed and constructed based on laser beam intensity. This device calculates the frequency of the bubble formation by measuring the total time of the formation p...