A New Method for Ion Collection System Using Magnetic Levitation Electrode
نویسندگان
چکیده
منابع مشابه
Selective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.
A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...
متن کاملOutput feedback control of a mechanical system using magnetic levitation.
This paper presents an application of a nonlinear magnetic levitation system to the problem of efficient active control of mass-spring-damper mechanical systems. An output feedback control scheme is proposed for reference position trajectory tracking tasks on the flexible mechanical system. The electromagnetically actuated system is shown to be a differentially flat nonlinear system. An extende...
متن کاملA High-Precision Positioning System Using Magnetic Levitation∗
High accuracy positioning stages with multiple degrees-of-freedom are ubiquitous in industrial manufacturing. Examples include probing and inspection systems, disk drive head assembly systems, and photolithographic positioning stages (microsteppers) in semiconductor manufacturing. Microsteppers are typically made of a lower-stage that actuates large high-speed movements and an upper-stage that ...
متن کاملLanthanum(III) Ion Selective Electrode Based on a New Ionophore
A PVC membrane electrode based on 1-[({[(butylsulfunyl)carbothioyl]disulfanyl} carbothioyl)sulfanyl]butane as a suitable ion carrier for determination of lanthanum(III) ion was prepared. This electrode revealedsuch a good selectivity toward La3+ ion over a wide variety of other metal ions. Some experimental parametersuch as membrane composition, nature, and amount of plasticizer, the amount of ...
متن کاملOptimization of Magnetic Levitation System
In magnetically levitated system in certain applications like magnetically levitated train or bearingless motors the distance between the magnet and the levitated object has to be constant. The nonlinear system in such cases can be linearized and transfer function of the system is obtained. But a proper controller is required to manipulate the current through the magnet coil. The simplest contr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: RADIOISOTOPES
سال: 1999
ISSN: 0033-8303,1884-4111
DOI: 10.3769/radioisotopes.48.1