A new position-sensitive detector for thermal and epithermal neutrons
نویسندگان
چکیده
منابع مشابه
A Position-Sensitive Ionization Chamber for Thermal Neutrons
A position-sensitive neutron detector based on He is being developed for a national crystal backscattering spectrometer (CBS) at a pulsed neutron source. It comprises a single gas volume, of constant depth, in the form of an annulus that is also part of a truncated cone. Charge from each event is collected on one or two anode strips, out of a total 336 around the annulus, yielding an angular re...
متن کاملHigh-pressure Helium-3 Scintillation Position-sensitive Detector of Thermal Neutrons
The objective of this study is to demonstrate the feasibility of constructing a compact neutron detector that is sensitive to thermal and epithermal neutrons and has high rejection efficiency relative to gamma-ray background. A two-channel high-pressure He scintillation detector is considered for the detection of neutrons in coincidence mode. The detector consists of two large avalanche photodi...
متن کاملA Position Sensitive Detector for 1 - 10 MeV Gamma RaysJoel
A position sensitive detector for 9 MeV gamma rays has been developed as part of a contraband detection system for airports. The system images contraband, such as explosives or drugs, in a geometry similar to medical x-ray computed tomography. A point source of gamma rays shines through an unknown object. Transmission projections of the areal density of detected gamma rays are reconstructed int...
متن کاملSelf-Balancing Position-Sensitive Detector (SBPSD)
Optical position-sensitive detectors (PSDs) are a non-contact method of tracking the location of a light spot. Silicon-based versions of such sensors are fabricated with standard CMOS technology, are inexpensive and provide a real-time, analog signal output corresponding to the position of the light spot. An innovative type of optical position sensor was developed using two back-to-back connect...
متن کاملActivation Measurements for Thermal Neutrons
The neutron energy spectrum from the atomic bomb consisted of a range of energies from thermal to fast neutrons. Fast neutrons contribute a larger dose to the human body than lowenergy neutrons per unit flux. The evaluation of the fast neutron component has been performed based on analyses of P (>3 MeV) activity measured immediately after the Hiroshima bomb and Ni (>2 MeV), which has a much lon...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods
سال: 1978
ISSN: 0029-554X
DOI: 10.1016/0029-554x(78)90330-0