A New Three-Phase Three-Winding Transformer Electromagnetic Transient Model
نویسندگان
چکیده
منابع مشابه
overvoltage caused by winding terminal arrangement of three phase transformer
usually both ends of a transformer winding are at the same side of the magnetic core. with this arrangement there are automaticaly the same number of the turns for each winding in both core windows next to the middle leg of a three phase three leg core type transformer. contrary to this arrangement it is possible to put the two ends of a winding at the different sides of the core. in this case ...
متن کاملImprovement of Electromagnetic Forces in a Single-Phase Induction Motor by Providing a New Winding Distribution
Single-phase induction motors have a wide range of domestic and industrial applications. These motors have a squirrel cage rotor and their stator usually has two windings: main and auxiliary. The use of auxiliary winding in the structure of single-phase induction motors creates two unbalance and asymmetric phases. This causes to increase the spatial harmonics of the field in the air gap, and al...
متن کاملHigh-Frequency Modeling and Simulation of a Single-Phase Three-Winding Transformer Including Taps in Regulating Winding
—Transformer terminal equivalents obtained via admittance measurements are suitable for simulating high-frequency transient interaction between the transformer and the network. This paper augments the terminal equivalent approach with a measurement-based voltage transfer function model which permits calculation of voltages at internal points in the regulating winding. The approach is demonstrat...
متن کاملCharacterization of Power Transformer Electromagnetic Forces Affected by Winding Faults
Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...
متن کاملA Novel Transformer-Based Single-to-Three Phase Conversion Technique Using Rotating Magnetic Field Theory
This paper presents a new single to three phase converter using rotating magnetic field transformer. Conventional transformers have been used in many converters aiming at supplementary improvements and they usually have no critical effect on the conversion technique. In this paper, the conversion technique is based on a special rotating magnetic field transformer in which there are two windings...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Smart Grid and Clean Energy
سال: 2013
ISSN: 2315-4462
DOI: 10.12720/sgce.2.1.40-45