A new use for the amplatzer duct occluder device.

We report a case in which the Amplatzer device for percutaneous occlusion of ductus arteriosus was successfully used for occluding a large systemic-pulmonary collateral vessel in a patient who had previously undergone surgery for correction of pulmonary atresia and ventricular septal defect (Rastelli technique), and was awaiting the change of a cardiac tube. In the first attempt, the device emb...

متن کامل

Transcatheter closure of large sized patent ductus arteriosus using the amplatzer duct occluder device.

OBJECTIVE To assess the results of anterograde transcatheter closure of a large sized patent ductus arteriosus using the Amplatzer Duct Occluder (ADO) device. STUDY DESIGN A case series. PLACE AND DURATION OF STUDY Department of Cardiology, Armed Forces Institute of Cardiology and National Institute of Heart Diseases, Rawalpindi, from January 2005 to December 2007. METHODOLOGY All patient...

متن کامل

The Amplatzer duct occluder: experience in 209 patients.

OBJECTIVES The aim of the study was to assess the safety and efficacy of the Amplatzer ductal occluder (ADO) in transcatheter occlusion of patent ductus arteriosus (PDA). BACKGROUND Transcatheter closure of small to moderate sized PDAs is an established procedure. The ADO is a self-expandable device with a number of salutary features, notably its retrievability, ease of delivery via small 5F ...

متن کامل

Transcatheter closure of postsurgical ruptured sinus of Valsalva with Amplatzer Duct Occluder II AS™ device

Sinus of Valsalva (SV) rupture is a rare, cardiac complication after surgical repair of complex congenital heart disease. This paper reports a 4-year-old male child with double outlet right ventricle (RV) and pulmonary stenosis with superior-inferior arrangement of the ventricles, who was submitted to surgical repair using the "reparation a l'etage ventriculaire" procedure. A few months after a...

متن کامل

Percutaneous Forceps Retrieval of an Embolized Amplatzer Duct Occluder

Transcatheter closure of patent ductus arteriosus with the Amplatzer duct occluder shows excellent results. However, there is a risk of device embolization after deployment. We report the case of a 33-year-old man in whom an embolized Amplatzer device was retrieved from the right pulmonary artery by a percutaneous method. We also review this uncommon severe complication and offer technical tips...