A Novel 13-step Diagonal/Sequential Measurement Method for Error Measurement and Compensation of Linear Axis Machining Center
نویسندگان
چکیده
منابع مشابه
A Novel Method for Human Astigmatism Formulation and Measurement
Astigmatism’s defect has not yet been formulated in Physics and medical physics books theoretically. In this paper, we are trying to formulate the astigmatism’s defect. The results of formulation show that “the degree of astigmatism is negative reverse the distance that vision’s condition of astigmatism’s chart lines change conditions in dimness angle from dimness condition at infinite distance...
متن کاملA Novel Method for Human Astigmatism Formulation and Measurement
Astigmatism’s defect has not yet been formulated in Physics and medical physics books theoretically. In this paper, we are trying to formulate the astigmatism’s defect. The results of formulation show that “the degree of astigmatism is negative reverse the distance that vision’s condition of astigmatism’s chart lines change conditions in dimness angle from dimness condition at infinite distance...
متن کاملDetection of Outliers and Influential Observations in Linear Ridge Measurement Error Models with Stochastic Linear Restrictions
The aim of this paper is to propose some diagnostic methods in linear ridge measurement error models with stochastic linear restrictions using the corrected likelihood. Based on the bias-corrected estimation of model parameters, diagnostic measures are developed to identify outlying and influential observations. In addition, we derive the corrected score test statistic for outliers detection ba...
متن کاملA simple and novel method for acoustic streaming power measurement of ultrasonic horn
Ultrasonic horn with transfer of acoustic wave into an aqueous solution results in unique properties. When, transfer of sound wave into a liquid results in liquid movement in the direction of wave propagation which gradually loses its energy due to the viscous friction. This wave motion induces a flow which is known as acoustic streaming or micro-streaming. In this article, a simple innovative ...
متن کاملa novel method for human astigmatism formulation and measurement
astigmatism’s defect has not yet been formulated in physics and medical physics books theoretically. in this paper, we are trying to formulate the astigmatism’s defect. the results of formulation show that “the degree of astigmatism is negative reverse the distance that vision’s condition of astigmatism’s chart lines change conditions in dimness angle from dimness condition at infinite distance...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: DEStech Transactions on Engineering and Technology Research
سال: 2019
ISSN: 2475-885X
DOI: 10.12783/dtetr/ecae2018/27761