A novel noninvasive method to detect rejection after heart transplantation
نویسندگان
چکیده
منابع مشابه
A novel noninvasive method to detect rejection after heart transplantation
Prompt and accurate detection of rejection prior to pathological changes after organ transplantation is vital for monitoring rejections. Although biopsy remains the current gold standard for rejection diagnosis, it is an invasive method and cannot be repeated daily. Thus, noninvasive monitoring methods are needed. In this study, by introducing an IL-2 neutralizing monoclonal antibody (IL-2 N-mA...
متن کاملNoninvasive monitoring of infection and rejection after lung transplantation.
The survival rate following lung transplantation is among the lowest of all solid-organ transplants, and current diagnostic tests often fail to distinguish between infection and rejection, the two primary posttransplant clinical complications. We describe a diagnostic assay that simultaneously monitors for rejection and infection in lung transplant recipients by sequencing of cell-free DNA (cfD...
متن کاملIdentification of Novel and Noninvasive Biomarkers of Acute Cellular Rejection After Liver Transplantation by Protein Microarray
BACKGROUND Acute cellular rejection (ACR) is one of the main factors in transplanted organ failure in liver transplantation. A precise marker for diagnosing or predicting rejection is not currently available; therefore, invasive liver biopsy is standard procedure. To develop a noninvasive method for precise diagnosis of ACR, we evaluated autoantibodies from patient sera as potential biomarkers ...
متن کاملA Novel Interference Rejection Method for GPS Receivers
This paper proposes a new method for rejecting the Continuous Wave Interferences (CWI) in the Global Positioning System (GPS) receivers. The proposed filter is made by cascading an adaptive Finite Impulse Response (FIR) filter and a Wavelet Packet Transform (WPT) based filter. Although adaptive FIR filters are easy to implement and have a linear phase, they create self-noise in the rejection of...
متن کاملA Novel Method to Detect β-Cyclodextrin Glucosyl Transferase (β-CGTase) Activity on Polyacrylamide Gels
b-cyclodextrin glucosyl transferase (b-CGTase) hydrolyses starch to produce b-cyclodextrin by transglycosylation (cyclization) activity. The conventional method for detection of b-CGTase activity is based on detecting starch hydrolysis by iodine staining. This method reveals all amylolytic enzymes, but can not discriminate them. In the present study, we introduce a new method for specific detec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Brazilian Journal of Medical and Biological Research
سال: 2012
ISSN: 0100-879X
DOI: 10.1590/s0100-879x2012007500164