Multiflow Roller Pump Module
Pump failures are an inherent problem associated with the operation of a heart lung machine. This report details the observation and identification of an unusual modular pump failure. Pump stoppage occurred intermittently over a period of two months with two separate Stockert/Shiley Computer Aided Perfusion System (CAPS) consoles. The mechanism was identified as a static discharge transferred t...
متن کاملTygon" Roller Pump Tubing
A failure analysis was performed on Norton S-65-HL Tygon® tubing. Fatigue testing was performed on four sizes of this tubing, and essentially showed how the tubing wears out. A dynamic "life hours to failure" test, which was performed on the 3/8" internal diameter (ID) size, quantified when the tubing ruptured. Based on results of laboratory testing and the institution's clinical extracorporeal...
متن کاملTubing failure during prolonged roller pump use: a laboratory study.
Little is known about the mechanical forces acting on extracorporeal circuit tubing with prolonged roller pump use during extracorporeal membrane oxygenation (ECMO). We examined the time to tubing rupture of three different materials during actual roller pump use, mean and standard deviation (SD) (SD shown in parentheses): Tygon (control) 243.7 h (175.4); LVA 121 h (14.3); and SRT 6.6 h (2.1). ...
متن کاملNon-occlusive condition with the Better-Header roller pump: impacts of flow dynamics and hemolysis.
PURPOSE Impacts on hemolysis and backflow using a non-occlusive setting with the Better-Header (BH) roller pump were investigated. METHODS AND RESULTS Pump flow of a non-occlusion setting was measured with a pump speed of 3 L/min and 5 L/min against various after-loads. With the non-occlusive setting (BH-NO350), backflow was less than 10% if the pump pressure head was <300 mmHg. When the outl...
متن کاملAn under-occluded roller pump is less hemolytic than a centrifugal pump.
The purpose of this study is to measure and compare the hemolysis produced by roller pumps with varied occlusion settings and a centrifugal pump. The null hypothesis is that there is no difference in the Index of Hemolysis (IH = gm Hb/100 L pumped) produced by a roller pump (RP) at four different occlusion settings and a centrifugal pump (CP) at the same blood flow rate (4.5 L/min) and afterloa...