A numerical method for analyzing a passive fault current limiter considering hysteresis
نویسندگان
چکیده
منابع مشابه
Influence of Fault Current Limiter in Voltage Drop and TRV Considering Wind Farm
Influence of distributed generation systems in the distribution systems can increase the level of short-circuit current. The effectiveness of distributed generation systems is affected by the size, location, type of distributed generation systems technology, and the methods of connecting to distribution systems. Wind turbine system is the examples of distributed generation source. Not only does...
متن کاملFault Current Limiter for a Distributed Power System
The up-gradation of an Electrical power generation network results in higher levels of short circuit fault current. Thereby, the existing protection equipment like circuit breakers, isolators and fuses become under capacity and not capable of withstanding higher short circuit currents. Thus the system is highly vulnerable to the adverse effects of short circuits. Replacing the whole protection ...
متن کاملStudy of Superconducting Fault Current Limiter Device in a AC Railway System
Development of the electric networks led to more interconnection in this system, therefore high level of short circuit faults flows in the networks. Many destructive damages such as instability, insulation problems and voltage mitigation can highly play unwanted influences on the system’s equipment. Using appropriate protection devices like high voltage fuses, fast switches, and such devices...
متن کاملFinite element modeling of a superconducting fault current limiter
This paper summarizes the work done to show finite element modeling results on a high temperature superconductor fault current limiter (FCL). The paper also gives the small mock-up design of the matrix FCL and its finite element model (FEM). It also discusses the limitations of the FEM and explains how the results from the FEM compare with the experimental data derived for the configuration. A ...
متن کاملOptimal Placement and Sizing of Fault Current Limiter in a Real Network: a Case Study (TECHNICAL NOTE)
In this paper, the effect of number and fault current limiter(FCL) location has been investigated in order to have maximum reduction of short circuit current level in all buses in a real network. To do so, the faulty buses were identified in terms of short circuit current level by computing short circuits on the desired network. Then, while the fault current limit was modeled, its optimal locat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Magnetics
سال: 1998
ISSN: 0018-9464
DOI: 10.1109/20.706789