A physiological model of factors that determine skeletal muscle hemoglobin oxygen saturation
نویسندگان
چکیده
منابع مشابه
Stimulation characteristics that determine arteriolar dilation in skeletal muscle.
To determine the skeletal muscle stimulation parameters that are most important in establishing vasodilation in the microvasculature, I tested whether arteriolar diameter during 2 min of repetitive, short-duration, tetanic skeletal muscle contractions increased with changes in stimulus frequency, stimulation train duration, and contraction frequency. To test this, the diameter of transverse art...
متن کاملEffects of ionic parameters on behavior of a skeletal muscle fiber model
All living cells have a membrane which separates inside the cell from it's outside. There is a potential difference between inside and outside of the cell. This potential difference will change during an action potential. It is quite common to peruse action potentials of skeletal muscle fibers with the Hodgkin-Huxley model. Since Hodgkin and Huxley summarized some controlling currents like inwa...
متن کاملA tri state mechanism for oxygen release in fish hemoglobin: Using Barbus sharpeyi as a model
Hemoglobin is a porphyrin containing protein with an a2b2 tetrameric structure and like other porphyrin compounds shows spectral behavior of species specific characteristics. Researchers tend to relate bands in the hemoglobin spectra to certain structural and/or functional features. Given the fact that hemoglobin is the main oxygen carrier in animals functioning through the Oxy«Deoxy equilibriu...
متن کاملClinical accuracy of continuous hemoglobin oxygen saturation monitoring devices.
Three devices used to measure hemoglobin oxygen saturation in the extracorporeal circuit were studied and compared to a control. The Baxter Bentley OxySat, Oximetrix Accusat, and Radiometer ABL4 blood gas monitor were compared to a control, the IL 282 Co-Oximeter. Fifty-one sample points were obtained during all phases of cardiopulmonary bypass with results as follows: table: see text. The Ac...
متن کاملHemoglobin oxygen saturation measurements using resonance Raman intravital microscopy.
A system is described for in vivo noninvasive measurements of hemoglobin oxygen saturation (HbO2Sat) at the microscopic level. The spectroscopic basis for the application is resonant Raman enhancement of Hb in the violet/ultraviolet region, allowing simultaneous identification of oxy- and deoxyhemoglobin with the same excitation wavelength. The heme vibrational bands are well known, but the tec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The FASEB Journal
سال: 2010
ISSN: 0892-6638,1530-6860
DOI: 10.1096/fasebj.24.1_supplement.445.3