A proposed empirical corrosion model for reinforced concrete
                    
                        
                            نویسندگان
                            
                            
                        
                        
                    
                    
                    چکیده
منابع مشابه
investigating the feasibility of a proposed model for geometric design of deployable arch structures
deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...
Corrosion Monitoring of Reinforced Concrete Structures - A Review
Reinforced concrete structures have the potential to be very durable and capable of withstanding a variety of adverse environmental conditions. However, failures in the structures do still occur as a result of premature reinforcement corrosion. The maintenance and repair of bridges and buildings for their safety requires effective inspection and monitoring techniques for assessing the reinforce...
متن کاملMonitoring Corrosion of Steel Bars in Reinforced Concrete Structures
Corrosion of steel bars embedded in reinforced concrete (RC) structures reduces the service life and durability of structures causing early failure of structure, which costs significantly for inspection and maintenance of deteriorating structures. Hence, monitoring of reinforcement corrosion is of significant importance for preventing premature failure of structures. This paper attempts to pres...
متن کاملFRP Repair of Corrosion-Damaged Reinforced Concrete Beams
Corrosion of steel reinforcement is one of the main durability problems facing reinforced concrete infrastructures worldwide. This paper will summarize the results of a multi-phase experimental program undertaken at the University of Waterloo to investigate the viability of using externally bonded fiber reinforced polymer (FRP) laminates to rehabilitate corrosion-damaged reinforced concrete bea...
متن کاملEffect of Water-cement Ratio on Corrosion of Reinforced Concrete
Corrosion of reinforced concrete is one of the major problems in the construction industry causing premature deterioration of concrete structures well before their service life. This has placed incredible financial burden on many projects and also placed safety of users at risk. A research work was carried out to evaluate the effect of water cement ratio on corrosion of steel in reinforced conc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Structures <html_ent glyph="@amp;" ascii="&"/> Buildings
سال: 2002
ISSN: 0965-0911
DOI: 10.1680/stbu.152.1.79.40888