A Sequential Integration between Optimal Flexible Heat Exchanger Network Synthesis and Control Structure Design

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Heat Exchanger Network Synthesis Including Heat Transfer Equipment Design

This paper presents an optimisation model for the synthesis of heat exchanger networks (HEN) including the detailed design of the equipments formulated as a decomposition method. Shell and tube pressure drops and fouling are considered, as well as mechanical aspects, like shell and tube bundle diameters, internal and external diameter of tubes, number of tubes, number of baffles, number of shel...

متن کامل

Control structure design for optimal operation of heat exchanger networks

When only single bypasses and utility duties are used as manipulations, optimal operation of heat exchanger networks (HENs) can be categorized as an active constraint control problem. This work suggests a simple split-range control scheme to implement the optimal operation. The control structure can be found by solving an integer-linear programming (ILP) problem with two objective functions pro...

متن کامل

Flexible Energy Management and Heat Exchanger Network Design

The design of heat exchanger networks (HEN) is a well-studied problem in process synthesis and an ideal test base to benchmark methods and techniques in the field. Despite a significant number of relevant publications, networks are still designed under assumptions of fixed operating conditions. Significant variations in supply and demand, alongside a need for efficient management in energy mark...

متن کامل

Multivariable Optimal Control of a Heat Exchanger Network with Bypasses

Heat exchanger networks present an interesting control problem due to coupling among process streams. In this work, the linear quadratic regulator (LQR), a feedback optimal control technique, is used to control stream temperatures on a laboratory scale heat exchanger network, through bypass manipulation, in a multivariable system. The LQR design was based on a mathematical model of the plant an...

متن کامل

Low-level flexible-structure control applied to heat exchanger networks

A low-level flexible-structure control is proposed for designing control systems capable of efficiently handling constraints on the manipulated variables of heat exchanger networks (HENs). Flexible-structure refers to the capability of the resulting control system to switch from one closed-loop structure to another in order to keep regulation, and low-level means that it can be configured in mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Industrial & Engineering Chemistry Research

سال: 2018

ISSN: 0888-5885,1520-5045

DOI: 10.1021/acs.iecr.8b01611