A SILICON PHOTODIODE ARRAY DETECTOR COVERING A LARGE SOLID ANGLE FOR FLUORESCENCE EXAFS MEASUREMENTS FROM 2 TO 25 keV

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A SILICON PHOTODIODE ARRAY DETECTOR COVERING A LARGE SOLID ANGLE FOR FLUORESCENCE EXAFS MEASUREMENTS FROM 2 TO 25 keV

A Si-photodiode array detector operated in the photovoltaic mode is shown to offer several advantages over other fluorescence detectors: high efficiency, perfect linearity of the response, vacuum compatibility for soft X-ray measurements, absence of gas and voltage supplies. Low temperature cooling down to 120°c is needed in order to decrease the dark current and thermal noise of the shunt resi...

متن کامل

Compact solid-state CMOS single-photon detector array for in vivo NIR fluorescence lifetime oncology measurements.

In near infrared fluorescence-guided surgical oncology, it is challenging to distinguish healthy from cancerous tissue. One promising research avenue consists in the analysis of the exogenous fluorophores' lifetime, which are however in the (sub-)nanosecond range. We have integrated a single-photon pixel array, based on standard CMOS SPADs (single-photon avalanche diodes), in a compact, time-ga...

متن کامل

Large area avalanche photodiode detector array upgrade for a ruby-laser Thomson scattering system

A low-cost upgrade has been implemented on the Madison Symmetric Torus ~MST! ruby-laser Thomson scattering ~TS! system to increase spectral coverage and substantially improve the signal-to-noise ratio ~SNR!. The spectral resolution has been increased from five channels on the long-wavelength side to an 11-channel system, which covers both sides of the laser line. Coverage on both sides of the s...

متن کامل

A liquid-helium cooled large-area silicon PIN photodiode x-ray detector

An x-ray detector using a liquid-helium cooled large-area silicon PIN photodiode has been developed along with a tailor-made charge sensitive preamplifier whose firststage JFET has been cooled. The operating temperature of the JFET has been varied separately and optimized. The xand γ-ray energy spectra for an Am source have been measured with the photodiode operated at 13 K. An energy resolutio...

متن کامل

A Practical Solution for 77 K Fluorescence Measurements Based on LED Excitation and CCD Array Detector

The fluorescence emission spectrum of photosynthetic microorganisms at liquid nitrogen temperature (77 K) provides important insights into the organization of the photosynthetic machinery of bacteria and eukaryotes, which cannot be observed at room temperature. Conventionally, to obtain such spectra, a large and costly table-top fluorometer is required. Recently portable, reliable, and largely ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Le Journal de Physique Colloques

سال: 1986

ISSN: 0449-1947

DOI: 10.1051/jphyscol:1986826