A Spatial Compounding Method for Non-Delayed Sequential Beamforming

نویسندگان

چکیده

We present a new spatial compounding method to improve the contrast of ultrasonic images for non-delayed sequential beamforming (NDSB). Sequential adopts more than one beamformer reconstruct B-mode which has advantage simple front-end electronics and fast data transfer rate. Via field pattern analysis, we propose where two sub-images can be reconstructed along with NDSB sub-image. These seen as being produced different transmit origins; thus, their summation enhances image contrast. Image quality was analyzed in terms resolution, ratio (CR), contrast-to-noise (CNR). The proposed improves lateral resolution up 41%. In vitro results confirm 13.0-dB CR 4.0-dB CNR improvement. vivo reveal 10.9-dB 6.0-dB improvement cross-section jugular vein 8.0-dB 4.5-dB longitudinal-section carotid artery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new method of spatial compounding imaging.

A new method of spatial compound imaging is presented that improves image quality without the usual requirement to decrease the frame rate. The new method of imaging utilizes three transducers for data acquisition. The transducer located at the center of the transducer system is a phased array probe that acts as both transmitter and receiver. The other transducers are unfocused pistons that act...

متن کامل

Phased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test

One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...

متن کامل

Phased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test

One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...

متن کامل

A Statistical Method for Sequential Images – Based Process Monitoring

Today, with the growth of technology, monitoring processes by the use of video and satellite sensors have been more expanded, due to their rich and valuable information. Recently, some researchers have used sequential images for image defect detection because a single image is not sufficient for process monitoring. In this paper, by adding the time dimension to the image-based process monitorin...

متن کامل

Joint Temporal-spatial Reference Beamforming: Eig Beamforming

Traditional methods for beamforming can be grouped in two families, the time reference beamformer and the spatial reference beamforming. Nevertheless, the increasing demand on receivers for location systems and high bandwidth over frequency selective fading able to properly manage multipath and co-channel interference motivates the need for versatile processing able to cope with both problems. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Applied sciences

سال: 2021

ISSN: ['2076-3417']

DOI: https://doi.org/10.3390/app11199200