Can a Pressure Standard be Based on Capacitance Measurements?
We consider the feasibility of basing a pressure standard on measurements of the dielectric constant ϵ and the thermodynamic temperature T of helium near 0 °C. The pressure p of the helium would be calculated from fundamental constants, quantum mechanics, and statistical mechanics. At present, the relative standard uncertainty of the pressure ur(p) would exceed 20 × 10-6, the relative uncertain...
متن کاملA Comparison of the effectiveness of Mammographic Film-Screen and Standard Film-Screen in the Detection of Small Bone Fractures
The use of mammography film-screen is limited in general radiography. The purpose of this study was to compare the effectiveness of mammographic film-screen and standard film-screen systems in the detection of small bone fractures. Radiographs were taken from patients' extremities and neck areas using mammography film-screen and standard film-screen (n=57 each). Fourteen other radiographs were ...
متن کاملModeling of capacitance and sensitivity of a MEMS pressure sensor
In this paper modeling of capacitance and sensitivity for MEMS capacitive pressure sensor is presented. In capacitive sensor the sensitivity is proportional to deflection and capacitance changes versus pressure. Therefore first the diaphragm displacement, capacitance and sensitivity of sensor with square diaphragm have been modeled and then simulated using finite element method (FEM). It can b...
متن کاملA high precision method for measuring very small capacitance changes
A novel method for measuring very small capacitance changes based on capacitance-to-phase angle conversion is introduced in this article. This new method is the improved or linearized version of the nonlinear capacitance-to-phase angle conversion method. The main features of this scheme are the very good linearity, extremely high stray immunity and a very high resolution. The experimental resul...
متن کاملCapacitance of a tube
The electrostatic problem of a hollow, conducting tube of finite length held at a fixed potential is solved using two methods. A twoterm Galerkin solution is constructed for the surface distribution of induced charge. The sum of a uniform component and a simple edgecondition term provides a variational solution to the dual integral equations that are the equations-of-motion for the mixed bounda...