A Study on Effective Source-Skin Distance using Phantom in Electron Beam Therapy

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effective Source-Surface Distance in Various Field Sizes and Electron Beam Energies and its Effect on Cutout Factor in a Elekta Precise Linear Accelerator

Introduction: In electron beam treatment, because of the non-point electron beam source, inverse-square law cannot be applied for dosimetry in different treatment intervals. Therefore, providing source-surface distance (SSD) charts in all clinics is of paramount importance. This study aimed to determine the effective SSD for various electron beam energies and field sizes and to...

متن کامل

A Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom

Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D) XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion...

متن کامل

determining the effective source-surface distance for therapeutic electron beams

conclusions using the maximum dose depth from pdd curves and the inverse square law, the required ssdeff to calculate the dose distribution of the electron beam can be calculated. objectives the aim of this study was to determine the effective source-surface distance (ssdeff) of an electron linear accelerator (linac), and its dependence on energy and depth. materials and methods a varian linac ...

متن کامل

Electron beam therapy at extended source‐to‐surface distance: a Monte Carlo investigation

Electron-beam therapy is used to treat superficial tumors at a standard 100 cm source-to-surface distance (SSD). However, certain clinical situations require the use of an extended SSD. In the present study, Monte Carlo methods were used to investigate clinical electron beams, at standard and non-standard SSDs, from a Siemens Oncor Avant Garde (Siemens Healthcare, Erlangen, Germany) linear acce...

متن کامل

Comparison of Electron-Beam Dose Distributions in a Heterogeneous Phantom Obtained Using Radiochromic Film Dosimetry and Monte Carlo Simulation

Introduction: Nowadays new radiochromic films have an essential role in radiotherapy dosimetry. Properties such as high sensitivity, good reproducibility, high spatial resolution, easy readout and portability have made them attractive for dosimetry, especially in high-dose-gradient regions. Material and Methods: In this study, electron-beam dose distributions in homogenous and heterogeneous pha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Magnetics

سال: 2014

ISSN: 1226-1750

DOI: 10.4283/jmag.2014.19.1.015