A Study on Management of Basicervical Neck Femur Fractures with Dynamic Hip Screw (DHS) and Derotation Screw Fixation
نویسندگان
چکیده
منابع مشابه
Comparing Therapeutic Outcomes of Dynamic Hip Screw and Multiple Cannulated Screws as Internal Fixation in Femoral Neck Fractures
Background and purpose: Femoral neck fracture is associated with a high rate of side effects, especially in young people, who are usually affected by severe energy shocks. Results after injury depend on some factors, including displacement, fragility, bleeding rate, proper placement, and stable and strong fixation. The aim of this study was to compare dynamic hip screw (DHS) or multiple cannula...
متن کاملType II Intertrochanteric Fractures: Proximal Femoral Nailing (PFN) Versus Dynamic Hip Screw(DHS)
Background: Intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. Dynamic Hip Screw (DHS) is still considered the gold standard for treating intertrochanteric fractures by many. Not many studies compare the DHS with Proximal femoral nail (PFN), in Type II intertrochanteri...
متن کاملA Comparative Study Of The Management Of Fracture Neck Femur By Dynamic Hip Compression Screw With Derotation Screw Versus Three Cancellous Screws
Background: Intracapsular fractures of neck femur have always presented a great challenge to orthopaedics surgeons and remain in many ways the unsolved fracture as far as treatment and results are concerned. Methods: Cases included in this study are transcervical and subcapital fracture neck femur in patients less than 60 yrs of age managed in Sir JJ Hospital, Mumbai -08. Results: Fracture type...
متن کاملTotal hip arthroplasty following failure of dynamic hip screw fixation of fractures of the proximal femur.
Thirty-two patients (11 male, 21 female) with a mean age of 64 years were prospectively studied after undergoing total hip replacement after failed treatment of intertrochanteric fractures. One patient had bilateral surgery. The mean time from primary surgery to the salvage arthroplasty was 15 months (range, 4 to 32 months). The mean follow-up period was 57 months (range, 30 to 108 months). Int...
متن کاملResults of Intertrochanteric Fractures Fixed with Dynamic Hip Screw Fixation
Numerous internal fixation devices have been used to stabilize intertrochanteric fracturesWe have analyzed the results of the intertrochanteric fractures treated with dynamic hip screw fixation. 33 patients (13 males, 20 females) were included. Range of age was 50-90 years, right side involved in 21 cases whereas left side in 12 cases and classified according to Boyd and griffin classification ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: SAS Journal of Surgery
سال: 2020
ISSN: 2454-5104
DOI: 10.36347/sasjs.2020.v06i08.005