A Study on SVL Transient Characteristics by Switching Overvoltage at Single Point Bonding Section in Underground Transmission Cables
نویسندگان
چکیده
منابع مشابه
Estimation of New Weighted Controlled Switching Overvoltage by RBFN Model
Mitigating switching overvoltages (SOVs) and conducting well-suited insulation coordination for handling stresses are very important in UHV transmission Lines. The best strategy in the absence of arresters is controlled switching (CS). Although elaborate works on electromagnetic transients are considered in the process of designing transmission systems, such works are not prevalent in day-to-da...
متن کاملTransient Characteristics of a Single-Effect Absorption Refrigeration Cycle
This paper deals with a lumped-parameter dynamic simulation of a single-effect LiBr-H2O absorption chiller. In many studies the thermodynamic properties of LiBr-H2O solution were taken from some approximate relations causing the results to be somewhat inaccurate. These relations were used to solve simultaneous differential equations involving the continuity of species constituting the LiBr-H2O ...
متن کاملSimulation of transient processes on overvoltage in electric transmission lines using ATP-EMTP
In this paper, the mathematical modeling and simulation of electromagnetic transient processes is considered, which is of vital importance for examining the overvoltage phenomenon of power transmission systems. In the mathematical models of the AC power transmission systems that contain a power source, the power transformer, transmission line, and power autotransformer block are presented. The ...
متن کاملa study on insurer solvency by panel data model: the case of iranian insurance market
the aim of this thesis is an approach for assessing insurer’s solvency for iranian insurance companies. we use of economic data with both time series and cross-sectional variation, thus by using the panel data model will survey the insurer solvency.
Calculating Intermediate Faults in Underground Cables
Short-circuit calculations are extremely important in the application and setting of protective relays and the analysis of power system operations. This paper illustrates the calculation of fault currents and voltages during intermediate faults in underground cables, taking into consideration the cable sheath bonding and grounding method. The compensated ground loop impedance for faults along t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Transactions of The Korean Institute of Electrical Engineers
سال: 2014
ISSN: 1975-8359
DOI: 10.5370/kiee.2014.63.6.764