A System-on-Chip Assay for Bilirubin Levels Measurement in Whole Blood

نویسندگان

چکیده

Bilirubin (BR) is clinically confirmed as a biomarker for liver health and used to assess the prognosis of cirrhosis. Optical chemical methods have been utilized blood BR biosensing. While optical offer real-time monitoring are handy immune infection, measurements may not be practical due instrument complexity space requirements. This study investigated dual-wavelength (DWL) technique estimation using system-on-chip (SoC). The SoC includes an module with blue (455 nm) green (530 LEDs which were DWL measurement. Porcine was surrogate human levels kept within pathophysiological ranges projected from healthy individuals (<1.2 mg/dL) cirrhotic patients (up 50 mg/dL). Our findings show high sensitivity in blood. lays groundwork point-of-care testing levels, primarily hyperbilirubinemia infants adults out homes or in-community settings.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A simplified assay for porphyrins in whole blood.

Recent investigations concerning the significance of porphyrins in erythrocytes indicate a need for a rapid quantitative assay, easily adaptable to routine clinical use. To till this need, we have developed a simplified procedure for the measurement of porphyrins (essentially protoporphyrin) in whole blood. Blood is stirred with acetone-ethyl acetate and the porphyrins are extracted with formic...

متن کامل

A simple assay for glutathione in whole blood.

A method for detecting glutathione selectively in whole blood deposited on filter paper is described. GSH is fractionated from proteins, hemoglobin and other potentially interfering components and determined using a resorufin-acrylate fluorescent probe. The relative standard deviation is lower than 5% (n = 5). Recoveries of GSH from whole blood are between 94% and 108.6%.

متن کامل

A real time PCR assay on blood for diagnosis of invasive candidiasis in immunocompromised patient

Background and Purpose: Invasive candidiasis (IC) is a significant cause of morbidity and mortality in patients with hematologic disorders and bone marrow transplant recipients. Rapid, specific and sensitive test for the timely accuracy in immunocompromised patients to reduce mortality rates and prevent IC progress is necessary. We established a real-time PCR assay on blood for the diagnosis an...

متن کامل

Whole-blood lymphocyte stimulation assay for measurement of cell-mediated immune responses in bovine brucellosis.

A study was conducted to develop an in vitro whole-blood lymphocyte stimulation assay for measurement of cell-mediated immune response in bovine brucellosis. A soluble antigen (BASA) prepared from killed cells of Brucella abortus 1119-3 was used. Cattle infected with B. abortus field strains, B. abortus 19 calfhood- and adult-vaccinated cattle, and nonexposed cattle were tested. Blood was dilut...

متن کامل

Comparison of Transcutaneous Bilirubin Measurement With Total Serum Bilirubin Levels in Preterm Neonates Receiving Phototherapy.

OBJECTIVE To compare transcutaneous bilirubin with total serum bilirubin in preterm neonates after initiation of phototherapy. METHODS Jaundice was assessed in 30 preterm neonates with transcutaneous bilirubin and total serum bilirubin before initiation of phototherapy and at 12 hr after initiation of phototherapy. A photo-occlusive patch was applied over the sternum. RESULTS Transcutaneous...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Engineering proceedings

سال: 2021

ISSN: ['2673-4591']

DOI: https://doi.org/10.3390/ecsa-8-11295