A technique for single-pulse spectrum and pulse width measurements for an IR-FEL

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation Pulse Compression for a SASE-FEL

The total radiation pulse consists of NS spikes, and the total pulse length is LP=NSLc. In a normal configuration all the spikes have the same line-width and the same central frequency. Chirping the pulse, i.e. changing the frequency of each spike by a quantity proportional to the spike longitudinal position inside the pulse, allow us to compress the pulse using a pair of diffraction gratings. ...

متن کامل

An efficient technique to select logic nodes for single event transient pulse-width reduction

This paper introduces an efficient method to identify logic nodes most likely to generate single-event transients. Selected nodes are hardened by gate resizing. This is integrated with temporal masking to increase fault tolerance.

متن کامل

Preliminary Design of Spacecraft Attitude Control with Pulse-Width Pulse-Frequency Modulator for Rest-to-Rest Maneuvers

In this paper, the preferred region of design parameters for quasi-normalized equations of single-axis attitude control of rigid spacecraft using pulse-width pulse-frequency modulator (PWPFM) is presented for rest-to-rest maneuvers. Using the quasi-normalized equations for attitude control reduces the system parameters, that is, the moment of inertia, the filter gain, and the maximum torque of ...

متن کامل

POLARIZATION HYSTERESIS CURVE MEASUREMENT FOR AN Au/PZT/YBCO DEVICE BY DOUBLE PULSE TECHNIQUE

Polarization for Au/Pb(Zr Ti )O /YBa Cu O ferroelectric capacitor has been studied and measured by pulse method. A sequence of pulses with amplitudes varying from 0 to 10 volts in 2 volt steps is applied and a conventional polarization curve is obtained by integrating the charge flow from the polarization switching induced by the voltage ramp. A value of 25?C/cm2 is measured for the satur...

متن کامل

Position Control of a Pulse Width Modulated Pneumatic Systems: an Experimental Comparison

In this study, a new adaptive controller is proposed for position control of pneumatic systems. Difficulties associated with the mathematical model of the system in addition to the instability caused by Pulse Width Modulation (PWM) in the learning-based controllers using gradient descent, motivate the development of a new approach for PWM pneumatics. In this study, two modified Feedback Error L...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

سال: 1993

ISSN: 0168-9002

DOI: 10.1016/0168-9002(93)90122-x