A Technique to Remove Cannulated Screws
نویسندگان
چکیده
منابع مشابه
A technique for removal of broken cannulated tricortical syndesmotic screws.
Breakage rates of tricortical syndesmotic screws after weight bearing range from 10% to 29%. Removal of the portion of the broken screw buried within the tibia often proves quite difficult. We report a new technique to remove a broken cannulated syndesmotic screw. This technique is simple, time saving, and less traumatic than previously reported methods of broken syndesmotic screw removal.
متن کاملArthrodesis of the knee using cannulated screws.
We retrospectively evaluated eight patients who underwent arthrodesis of the knee using cannulated screws. There were six women and two men, with a mean age of 53 years. The indications for arthrodesis were failed total knee arthroplasty, septic arthritis, tuberculosis, and recurrent persistent infection. Solid union was achieved in all patients at a mean of 6.1 months. One patient required aut...
متن کاملPercutaneous Cannulated Screws with Tension Band Wiring Technique in Patella Fractures
INTRODUCTION Most patellar fractures are transverse involving the central third. Open reduction and stabilization of transverse patellar fractures is indicated if there is more than 2-3 mm of fragment separation and/or articular incongruity. SURGICAL TECHNIQUE This study describes a percutaneous 2 cannulated screws and modified tension band wiring technique to treat transverse patellar fractu...
متن کاملA Novel Surgical Technique for Removing Buried Cannulated Screws Using a Guidewire and Countersink: A Report of Two Cases
Removal of metal implants is a common procedure that is performed for a variety of indications. However, problems such as a buried screw head may occasionally arise and render hardware removal difficult or even impossible. The problem is further compounded when the initial screw was inserted percutaneously or via a minimally-invasive (MIS) technique. In the present paper, we introduce a novel, ...
متن کاملPossible usage of cannulated pedicle screws without cement augmentation
BACKGROUND: The use of pedicle screws is becoming increasingly popular for spinal surgery practice as the technology advances. Screw pullout due to bone quality and loading conditions is one of the most common problems observed after pedicle screw fixation. Several solutions were studied to prevent screw pullout. These can be investigated under three main categories: screw design, expandable sc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Annals of The Royal College of Surgeons of England
سال: 2006
ISSN: 0035-8843,1478-7083
DOI: 10.1308/rcsann.2006.88.3.320b