A test beam setup for the characterization of the Geiger-mode avalanche photodiode technology for particle tracking
نویسندگان
چکیده
منابع مشابه
Advanced European Infrastructures for Detectors at Accelerators Journal Publication A test beam set-up for the characterization of the Geiger-mode avalanche photodiode technology for particle tracking
It is well known that avalanche photodiodes operated in the Geiger mode above the breakdown voltage offer a virtually infinite gain and time accuracy in the picosecond range that can be used for single photon detection. However, their performance in particle detection still remains unexplored. In this contribution, we are going to expose different steps that we have taken in order to prove the ...
متن کاملCharacterization of a Geiger-mode Avalanche Photodiode
A 32 by 32 array of packaged 100 μm Geiger-mode avalanche photodiodes were tested and characterized. A breakdown voltage of 32 V was measured; at or just above this voltage is where the device should be biased in order to operate in Geiger-mode. The ideal region of the forward biased IV curve resulted in an ideality factor of 1.0 and no recombination/generation region. In addition, IDL code was...
متن کاملthe test for adverse selection in life insurance market: the case of mellat insurance company
انتخاب نامساعد یکی از مشکلات اساسی در صنعت بیمه است. که ابتدا در سال 1960، توسط روتشیلد واستیگلیتز مورد بحث ومطالعه قرار گرفت ازآن موقع تاکنون بسیاری از پژوهشگران مدل های مختلفی را برای تجزیه و تحلیل تقاضا برای صنعت بیمه عمر که تماما ناشی از عدم قطعیت در این صنعت میباشد انجام داده اند .وهدف از آن پیدا کردن شرایطی است که تحت آن شرایط انتخاب یا کنار گذاشتن یک بیمه گزار به نفع و یا زیان شرکت بیمه ...
15 صفحه اولinvestigating the integration of translation technologies into translation programs in iranian universities: basis for a syllabus design in translation technology
today, information technology and computers are indispensable tools of any profession and translation technologies have become an indispensable part of translator’s workstation. with the increasing demands for high productivity and speed as well as consistency and with the rise of new demands for translation and localization, it is necessary for translators to be familiar with market demands an...
A Geiger-mode avalanche photodiode array for X-ray photon correlation spectroscopy.
X-ray photon correlation spectroscopy (XPCS) provides an opportunity to study the dynamics of systems by measuring the temporal fluctuations in a far-field diffraction pattern. A two-dimensional detector system has been developed to investigate fluctuations in the frequency range of several Hz to kHz. The X-ray detector system consists of a thin 100 microm scintillation crystal coupled to a Gei...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 2012
ISSN: 0168-9002
DOI: 10.1016/j.nima.2012.08.026