BACKGROUND The newest release of the Eclipse (Varian) treatment planning system (TPS) includes an optimizing engine for Elekta volumetric-modulated arc therapy (VMAT) planning. The purpose of this study was to evaluate this new algorithm and to compare it to intensity-modulated radiation therapy (IMRT) for various disease sites by creating single- and double-arc VMAT plans. METHODS A total of...
متن کاملTreatment Planning Considerations Using IMRT
Introduction ...........................................................103 IMRT or 3DCRT? ...................................................105 The MSKCC IMRT Planning Process....................107 Patient Selection • Patient Simulation And Structure Localization • Selection Of Beam Energy, Number, And Direction • Optimization • Conversion Of Intensity Profiles To Leaf Motion • Forward Dose ...
متن کاملPlanning for mARC treatments with the Eclipse treatment planning system
While modulated arc (mARC) capabilities have been available on Siemens linear accelerators for almost two years now, there was, until recently, only one treatment planning system capable of planning these treatments. The Eclipse treatment planning system now offers a module that can plan for mARC treatments. The purpose of this work was to test the module to determine whether it is capable of c...
متن کاملComparing experimental assessment of the peripheral dose outside the applicator in electron beams of ELEKTA with Treatment planning system
Introduction: The use of electrons in the electron therapy to destroy tumoral tissue is dedicated significant contribution of different methods of radiation therapy. Scattered radiation due to exited electrons of the applicator affect the dose out of the field in the patient's normal tissue. The aim of this study is to determine the peripheral dose outside the applicator in the...
متن کاملTreatment Couch Modeling in the Treatment Planning System Eclipse
The treatment couch and some of the positioning devices of patients receiving radiotherapy treatment are made of a material (carbon) which has low attenuation properties for the photon energies used in the radiotherapy. Previous investigations showed the suitability of carbon fiber tabletops in radiotherapy and their very low attenuation properties for a range of X-ray energies and field sizes ...