Absolute calibration of imaging plate for electron spectrometer measuring GeV-class electrons

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Broadband single-shot electron spectrometer for GeV-class laser-plasma-based accelerators.

Laser-plasma-based accelerators can provide electrons over a broad energy range and/or with large momentum spread. The electron beam energy distribution can be controlled via accurate control of laser and plasma properties, and beams with energies ranging from approximately 0.5 to 1000 MeV have been observed. Measuring these energy distributions in a single shot requires the use of a diagnostic...

متن کامل

Calibration of electron spectrometer resolution in attosecond streak camera.

We report a new method for determining the energy resolution of time-of-flight spectrometers for detecting photoelectrons produced with attosecond XUV pulses. By measuring the width of the 2s2p autoionization line of helium, we found the resolution of our spectrometer to be approximately 0.6 eV for electrons at 35.5 eV. Furthermore, the resolution in the 10 to 35 eV range was determined by appl...

متن کامل

Calibration Home Base for the Airborne Imaging Spectrometer Apex

ESA currently builds the airborne hyper-spectral push broom imaging spectrometer APEX operating in the spectral range from 380 to 2500 nm. In the scope of the APEX project a large variety of characterization measurements will be performed for verification of the instrument performance. Later, during the operational phases, regular instrument checks will be executed, i.e., on-board characterizat...

متن کامل

Absolute calibration of the antiproton detection efficiency for BESS below 1 GeV

An accelerator beam experiment was performed using a low-energy antiproton beam to measure the antiproton detection efficiency of the BESS detector. Measured and calculated efficiencies derived from the BESS Monte Carlo simulation based on geant/gheisha showed good agreement. With the detailed verification of the BESS simulation, results demonstrate that the relative systematic error of detecti...

متن کامل

Imaging Electrons in Few-Electron Quantum Dots

Electrons in a one-electron quantum dot were imaged in the Coulomb blockade regime at liquid He temperatures using a cooled scanning probe microscope (SPM). The SPM images are obtained by scanning a charged tip above the surface of the quantum dot and recording the conductance through the quantum dot in the Coulomb blockade regime as a function of tip position. The lowest energy level in the do...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Physics: Conference Series

سال: 2008

ISSN: 1742-6596

DOI: 10.1088/1742-6596/112/3/032073