Absolute frequency of 87Sr at 1.8 × 10−16 uncertainty by reference to remote primary frequency standards

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The absolute frequency of the 87Sr optical clock transition

The absolute frequency of the S0–P0 clock transition of 87Sr has been measured to be 429 228 004 229 873.65 (37) Hz using lattice-confined atoms, where the fractional uncertainty of 8.6 × 10−16 represents one of the most accurate measurements of an atomic transition frequency to date. After a detailed study of systematic effects, which reduced the total systematic uncertainty of the Sr lattice ...

متن کامل

Primary Atomic Frequency Standards at NIST

The development of atomic frequency standards at NIST is discussed and three of the key frequency-standard technologies of the current era are described. For each of these technologies, the most recent NIST implementation of the particular type of standard is described in greater detail. The best relative standard uncertainty achieved to date for a NIST frequency standard is 1.5×10(-15). The un...

متن کامل

Second Generation Cesium Fountain Primary Frequency Standards at NIST

NIST is currently investigating the design of a second-generation cesium-fountain primary frequency standard. The design goals of this standard include an ultimate frequency inaccuracy of δf/f < 10 and achievable stability better than σy(τ) < 10/τ. This standard is expected to eventually replace NIST-F1, the current U.S. primary frequency standard [1]. In the context of reaching frequency uncer...

متن کامل

Absolute frequency measurement of mid-infrared secondary frequency standard at BNM-LPTF

1 Absolute frequency measurement of Mid Infrared secondary frequency standard at BNM-LPTF G. D. Rovera, , Member, IEEE and O. Acef Abstract|An absolute frequency measurement of a CO2=OsO4 secondary frequency standard, operating in the mid infrared, is reported. A brief description of the measurement chain linking this standard to a hydrogen maser evidences the critical points. The measured freq...

متن کامل

‏‎a comparative study of language learning strategies employmed by bilinguals and monolinguals with reference to attitudes and motivation‎‏

هدف از این تحقیق بررسی برخی عوامل ادراکی واحساسی یعنی استفاده از شیوه های یادگیری زبان ، انگیزه ها ونگرش نسبت به زبان انگلیسی در رابطه با زمینه زبانی زبان آموزان می باشد. هدف بررسی این نکته بود که آیا اختلافی چشمگیر میان زبان آموزان دو زبانه و تک زبانه در میزان استفاده از شیوه های یادگیری زبان ، انگیزه ها نگرش و سطح مهارت زبانی وجود دارد. همچنین سعی شد تا بهترین و موثرترین عوامل پیش بینی کننده ...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Metrologia

سال: 2021

ISSN: 0026-1394,1681-7575

DOI: 10.1088/1681-7575/abc232