ABSOLUTE RADIOMETRIC CALIBRATION OF FY-2C INFRARED SPLIT-WINDOW CHANNELS BY USING SEA BUOY DATA AND NCEP REANALYSIS DATA
نویسندگان
چکیده
منابع مشابه
Assessment and Correction of on-Orbit Radiometric Calibration for FY-3 VIRR Thermal Infrared Channels
FengYun-3 (FY-3) Visible Infrared Radiometer (VIRR), along with its predecessor, Multispectral Visible Infrared Scanning Radiometer (MVISR), onboard FY-1C&D have had continuous global observation more than 14 years. This data record is valuable for weather prediction, climate monitoring, and environment research. Data quality is vital for satellite data assimilations in Numerical Weather Predic...
متن کاملGeneralized Split-Window Algorithm for Estimate of Land Surface Temperature from Chinese Geostationary FengYun Meteorological Satellite (FY-2C) Data
On the basis of the radiative transfer theory, this paper addressed the estimate ofLand Surface Temperature (LST) from the Chinese first operational geostationarymeteorological satellite-FengYun-2C (FY-2C) data in two thermal infrared channels (IR1,10.3-11.3 μ m and IR2, 11.5-12.5 μ m ), using the Generalized Split-Window (GSW)algorithm proposed by Wan and Dozier (1996). The coefficients in the...
متن کاملX-SAR radiometric calibration and data quality
This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any named products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained...
متن کاملRadiometric Calibration of Sar Image Data
Recent advances in calibration techniques have made calibrated SAR images, in which the data represents radar cross-section (0') or normalized radar cross-section (0'0), a reality. In this paper, some of these recent advances are discussed in the context of their impact on SAR sys'tem design, and in terms of the errors associated with each technique. The main sources of error in radiometric cal...
متن کاملAbsolute Radiometric Calibration of ALS Intensity Data: Effects on Accuracy and Target Classification
Radiometric calibration of airborne laser scanning (ALS) intensity data aims at retrieving a value related to the target scattering properties, which is independent on the instrument or flight parameters. The aim of a calibration procedure is also to be able to compare results from different flights and instruments, but practical applications are sparsely available, and the performance of calib...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: JOURNAL OF INFRARED AND MILLIMETER WAVES
سال: 2009
ISSN: 1001-9014
DOI: 10.3724/sp.j.1010.2009.00188