Absorbed dose to water determination for kilo-voltage X-rays using alanine/EPR dosimetry systems
نویسندگان
چکیده
Alanine's relative response to kilo-voltage X-rays, compared 60Co reference quality beam, was studied in this work, order determine correction factors be applied alanine's when irradiated with low medium energy X-rays (up 300 keV). The of Aerial's alanine dosimeters determined by three distinct methods: experimental measurements using and a calibrated PTW Farmer 30013 ion chamber, Monte Carlo simulations MCNPX code finally, analytical calculations based on weighting X-ray spectra NIST's published mass absorption coefficients. Two sets beam qualities, covering high voltages ranging from 50 kV up 280 kV, were used study the dependence dosimeter's response. Obtained results consistent within 2.1% (average standard deviation at k = 1).
منابع مشابه
Absorbed dose to water reference dosimetry using solid phantoms in the context of absorbed-dose protocols.
For reasons of phantom material reproducibility, the absorbed dose protocols of the American Association of Physicists in Medicine (AAPM) (TG-51) and the International Atomic Energy Agency (IAEA) (TRS-398) have made the use of liquid water as a phantom material for reference dosimetry mandatory. In this work we provide a formal framework for the measurement of absorbed dose to water using ioniz...
متن کاملAir Kerma Based Dosimetry versus Absorbed Dose to Water Based Dosimetry for High-energy Photon
Introduction: In the last 5 years the American Association of Physicists in Medicine Task Group 51 (AAPM TG-51) and the International Atomic Energy Agency (IAEA) published a new high-energy photon and electron dosimetry protocol. These protocols are based on the use of an ion chamber having an absorbed-dose to water calibration factor. These are different from the previous NCS report-2 and IAEA...
متن کاملTraceability to Absorbed-dose-to-water Primary Standards in Dosimetry of Brachytherapy Sources Used for Radiotherapy
− In the current brachytherapy practice, the procedures to determine the absorbed dose imparted to the patient are affected by an uncertainty higher than in radiotherapy with external beams. That could reduce the success of brachytherapy treatments. Most of the uncertainty is due to a lacking metrology: no absorbed-dose primary standards are so far available to assure direct traceability in dos...
متن کاملPotassium dithionate EPR dosimetry for determination of absorbed dose and LET distributions in different radiation qualities
Potassium dithionate EPR dosimetry for determination of absorbed dose and LET distributions in different radiation qualities. Abstract With an increasing interest in using protons and light ions for radiation therapy there is a need for possibilities to simultaneously determine both absorbed dose (D) and linear energy transfer, LET, (LΔ). Potassium dithionate (K2S2O6) tablets were irradiated in...
متن کاملComments on 'Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations'.
Current clinical experience in radiation therapy is based upon dose computations that report the absorbed dose to water, even though the patient is not made of water but of many different types of tissue. While Monte Carlo dose calculation algorithms have the potential for higher dose accuracy, they usually transport particles in and compute the absorbed dose to the patient media such as soft t...