Noninvasive Measurement of Gastric Propagation Using a Squid Magnetometer
A vector Superconducting QUuntum Interference Device (SQUID} magnetometer wus used to meusure the magnetic fields nssociated with propagation of gustric electrical uctivity. Measurements of the magnetic field vector were consistent with the presumed pattern of current propagation in the gastric musculature. Further studies using two SQUID systems ullowed the first noninvasive determination of t...
متن کاملEvaluation of a long-time temperature drift in a commercial Quantum Design MPMS SQUID magnetometer using Gd2O3 as a standard
The long-time temperature drift in a commercial Quantum Design MPMS SQUID magnetometer was evaluated using time-dependent magnetization measurements of Gd2O3. In contrast to earlier claims, the amplitude of the drift was found not to exceed 1-1.5 K. 30 minutes after system stabilization the temperature deviation did not exceed 0.2 K and the temperature was fully stabilized in less than 3 hours.
متن کاملDevelopment of High-Field ESR System Using SQUID Magnetometer and its Application to Measurement under High Pressure
We have developed a high-field and high-frequency ESR system using a commercially available magnetometer equipped with the superconducting quantum interference device (SQUID). This is magnetization detection type ESR and ESR is observed as a change of the magnetization at the resonance condition under irradiation of the electromagnetic wave. The frequency range is from 70 to 315 GHz and the max...
متن کاملThermal AC voltage standards with calculable AC-DC transfer difference in frequency range from 10 kHz to 1 MHz
Because Republic of Poland does not have its own primary AC voltage standard, we have been developing a set of standards which in the future can serve as national primary AC voltage standard. The set is composed of three standards with nominal input voltages UN of 1.5 V, 3 V and 6 V, respectively. The set covers AC voltage range from 0.7 V to 6 V. The voltage range will be extended to 0.5 ... 1...
متن کاملA New High Frequency Grid Impedance Estimation Technique for the Frequency Range of 2 to150 kHz
Grid impedance estimation is used in many power system applications such as grid connected renewable energy systems and power quality analysis of smart grids. The grid impedance estimation techniques based on signal injection uses Ohm’s law for the estimation. In these methods, one or several signal(s) is (are) injected to Point of Common Coupling (PCC). Then the current through and voltage of ...