Acceptor-like deep level defects in ion-implanted ZnO
نویسندگان
چکیده
منابع مشابه
Acceptor-like deep level defects in ion-implanted ZnO
Related Articles Donor behavior of Sb in ZnO J. Appl. Phys. 112, 033706 (2012) Transition levels of defects in ZnO: Total energy and Janak's theorem methods J. Chem. Phys. 137, 054709 (2012) Ab-initio studies on Li doping, Li-pairs, and complexes between Li and intrinsic defects in ZnO J. Appl. Phys. 111, 123713 (2012) Intrinsic and extrinsic defect relaxation behavior of ZnO ceramics J. Appl. ...
متن کاملDeep-level defects study of arsenic-implanted ZnO single crystal
of thesis entitled DEEP LEVEL DEFECTS STUDY OF ARSENIC IMPLANTED ZnO SINGLE CRYSTAL submitted by Congyong ZHU for the degree of Master of Philosophy at The University of Hong Kong in September 2008 Zinc oxide has recently received great attention because of its potential applications in the fields of spintronics and optoelectronics. P-type doping is one of the greatest issues that have to be ov...
متن کاملNitrogen is a deep acceptor in ZnO
Zinc oxide is a promising material for blue and UV solid-state lighting devices, among other applications. Nitrogen has been regarded as a potential p-type dopant for ZnO. However, recent calculations [Lyons, Janotti, and Van de Walle, Appl. Phys. Lett. 95, 252105 (2009)] indicate that nitrogen is a deep acceptor. This paper presents experimental evidence that nitrogen is, in fact, a deep accep...
متن کاملDeep electronic states in ion-implanted Si
In this paper we present an overview of the deep states present after ion-implantation by various species into n-type silicon, measured by Deep Level Transient Spectroscopy (DLTS) and high resolution Laplace DLTS (LDLTS). Both point and small extended defects are found, prior to any anneal, which can therefore be the precursors to more detrimental defects such as end of range loops. We show tha...
متن کاملExtended defects of ion-implanted GaAs
Ion-implantation-induced extended defect formation and annealing processes have been studied in GaAs. Mg, Be, Si, Ge, and Sn ions were implanted between 40 and 185 keV over the dose range of 1 X 10t3-1 X 1015/cm2. Furnace annealing after capping with S&N4 was performed between 700 and 900 “C for times between 5 min and 10 h. Plan-view and crosssectional transmission electron microscopy results ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Applied Physics Letters
سال: 2012
ISSN: 0003-6951,1077-3118
DOI: 10.1063/1.4720514