Accommodative Exercises to Lower Intraocular Pressure
نویسندگان
چکیده
منابع مشابه
Analysis of Accommodative Performance of a New Accommodative Intraocular Lens.
PURPOSE To compare objective and subjective accommodation and visual acuities with a new accommodative intraocular lens (IOL) (Lumina; AkkoLens Clinical BV, Rijswijk, The Netherlands) with a monofocal IOL and young phakic eyes. METHODS In this prospective, randomized controlled clinical investigation, patients aged 51 to 85 years with symptomatic cataract were enrolled in the study. A total o...
متن کاملProstaglandins E3 and D3 lower intraocular pressure.
The effects of the prostaglandin (PG)-3 series products PGE3 and PGD3 on the intraocular pressure of rabbits were studied. PGE3 at 0.001 and 0.01 mg/eye and PGD3 at 0.01 and 0.05 mg/eye doses were applied topically (in 50-microliters volume) to the normal rabbit eye. Both PGE3 and PGD3 significantly lowered intraocular pressure at all doses tested and the IOP lowering response lasted at least 2...
متن کاملAccommodative intraocular lenses for age-related cataracts.
The standard intraocular lens (IOL) that is used to replace a cataractous lens cannot change focus from distant to near objects, so most patients need glasses for near vision after cataract surgery. Limited evidence suggests that accommodative IOLs provide better near vision than monofocal IOLs, but not better than multifocal IOLs. Long-term follow-up is needed to confirm patient outcomes, and ...
متن کاملEvaluation of the diurnal intraocular pressure fluctuations and blood pressure under dehydration due to fasting
Introduction: This study aimed to investigate the diurnal intraocular pressure fluctuations under dehydration conditions and the relationship between the intraocular pressure fluctuations and blood pressure. Methods: The intraocular pressures (IOP), body weights, as well as systolic and diastolic blood pressures (SBP, DBP) of 36 fasting healthy volunteers were recorded at 8:00 a.m. and 5:00 p.m...
متن کاملDetermination of Central Venous Pressure from Intraocular Pressure
Background: In many clinical situations, knowledge of central venous pressure (CVP) is important. Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery. Those with carotid artery or jugular venous diseases as we...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Ophthalmology
سال: 2020
ISSN: 2090-0058,2090-004X
DOI: 10.1155/2020/6613066