Accuracy and Precision of Visual Stimulus Timing in PsychoPy: No Timing Errors in Standard Usage

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy and Precision of Visual Stimulus Timing in PsychoPy: No Timing Errors in Standard Usage

In a recent report published in PLoS ONE, we found that the performance of PsychoPy degraded with very short timing intervals, suggesting that it might not be perfectly suitable for experiments requiring the presentation of very brief stimuli. The present study aims to provide an updated performance assessment for the most recent version of PsychoPy (v1.80) under different hardware/software con...

متن کامل

the role of visual aids and translation in teaching vocabulary in est

the present study investigated the effect of the two vocabulary teaching techniques in est, namely the use of translation and the use of visual aids as two separate vocabulary teaching techniques. to answer the question of the study, a pretest (michigan test) was administered to the 58 randomly selected est students at khajeh nasiredin tusi university, faculty of mechanics. after the homogeneit...

15 صفحه اول

Timing and Counting Precision in the Blowfly Visual System

We measure the reliability of signals at three levels within the blowfly visual system, and present a theoretical framework for analyzing the experimental results, starting from the Poisson process. We find that blowfly photoreceptors, up to frequencies of 50-100 Hz and photon capture rates of up to about 3 · 10/s, operate well within an order of magnitude from ideal photon counters. Photorecep...

متن کامل

Timing and Counting Precision in the Blowfly Visual System

We measure the reliability of signals at three levels within the blowfly visual system, and present a theoretical framework for analyzing the experimental results, starting from the Poisson process. We find that blowfly photoreceptors, up to frequencies of 50-100 Hz and photon capture rates of up to about 3 · 10/s, operate well within an order of magnitude from ideal photon counters. Photorecep...

متن کامل

Spike Timing Precision in the Visual Front - End

To assess whether the output of the cat retina and LGN is sufficiently precise to support a temporal coding scheme, we determined whether spike timing in recorded spike trains is more precise than would be expected on the basis of the firing rate alone. We compared spike time deviations (temporal offsets between nearest spikes in subsequent responses to repeated presentations of the same stimul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: PLoS ONE

سال: 2014

ISSN: 1932-6203

DOI: 10.1371/journal.pone.0112033