Accuracy of biometric formulae for intraocular lens power calculation in a teaching hospital

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of intraocular lens power calculation in paediatric cataract surgery.

AIMS To determine the accuracy of intraocular lens (IOL) power calculation in a group of pseudophakic children. METHODS A retrospective analysis of biometric and refractive data was performed on 52 eyes of 40 infants and children, who successfully underwent cataract extraction and IOL implantation. The following parameters were included: age at the time of surgery, keratometry, axial length, ...

متن کامل

Accuracy of routine intraocular lens power calculation in a district general hospital.

To assess the accuracy of routine preoperative biometry we reviewed all cases of extracapsular cataract extraction with posterior chamber implant performed at Queen Alexandra Hospital in 1985. Of 471 eyes included in the survey 67.9% were within 1.0 D of the expected refraction and 90.7% within 2.0 D. Factors influencing accuracy are discussed. The necessity of routine preoperative biometry is ...

متن کامل

Matrix formula for intraocular lens power calculation.

The matrix calculation was applied to Gaussian optics. Matrices were defined for a single diopter, a lens, an association of two centered systems having the same axis when the origins are taken at the vertices of the first and last refracting surfaces. The matrix formula then was used to calculate the power of the emmetropizing lens implant, and its results compared with the ones obtained by fi...

متن کامل

Accuracy of formulae for secondary intraocular lens power calculations in pediatric aphakia

PURPOSE To compare the accuracy of axial length vergence formulas versus refractive vergence formulas for secondary intraocular lens (IOL) implantation in pediatric aphakia. METHODS This retrospective comparative study, evaluated 31 eyes of 31 patients aged ≤3.5 years, who had undergone secondary IOL implantation. The median absolute error (MedAE) was compared between axial length vergence fo...

متن کامل

ocular biometric changes after phacotrabeculectomy and its effect on intraocular lens power calculation

purpose: to evaluate ocular biometric changes after phacotrabeculectomy and its effect on intraocular lens power calculation. methods: twenty six eligible eyes (24 patients) underwent phacotrabeculectomy. they were reexamined at least 6 months after the operation in a historical cohort study. main outcome measures included axial length (al) with contact a- scan (us-8000, nidek, gamaguri, japan)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Ophthalmology

سال: 2020

ISSN: 2222-3959,2227-4898

DOI: 10.18240/ijo.2020.01.09