A transportable optical lattice clock
We present the experimental setup and first results of PTB’s transportable Sr clock. It consists of a physics package, several compact laser breadboards, and a transportable high finesse cavity for the clock laser. A comparison of the transportable system with our stationary optical lattice clock yields an instability of 2.2 × 10−15 √ s/τ for the transportable clock. The current fractional unce...
متن کاملProgress on the optical lattice clock
Mots-clés : Horloge optique Réseaux optiques Strontium Ytterbium Effet corps noir Stark Collisions froids Métrologie quantique Optical lattice clocks have made significant leaps forward in recent years, demonstrating the ability to measure time/frequency at unprecedented levels. Here we highlight this progress, with a particular focus on research efforts at NIST and JILA. We discuss advances in...
متن کاملProbing many-body interactions in an optical lattice clock
A. M. Rey1∗, A. V. Gorshkov, C. V. Kraus, M. J. Martin, M. Bishof, M. D. Swallows, X. Zhang, C. Benko, J. Ye, N. D. Lemke and A. D. Ludlow JILA, NIST and University of Colorado, Department of Physics, Boulder, CO 80309, USA ∗ E-mail: [email protected] 2 Joint Quantum Institute, NIST and University of Maryland, Department of Physics, College Park, MD 20742, USA Institute for Quantum Optic...
متن کاملA Fermi-degenerate three-dimensional optical lattice clock.
Strontium optical lattice clocks have the potential to simultaneously interrogate millions of atoms with a high spectroscopic quality factor of 4 × 1017 Previously, atomic interactions have forced a compromise between clock stability, which benefits from a large number of atoms, and accuracy, which suffers from density-dependent frequency shifts. Here we demonstrate a scalable solution that tak...
متن کاملOptical Cavity for the Strontium Lattice Atomic Clock
The Sr lattice atomic clock in Jun Ye’s group has been experiencing frequency shifts due to the interaction between the Sr atoms in the optical trap. One possible solution is to change the optical trap in the system such that the Sr atom density, and therefore the interaction between the atoms, is reduced. For this project a test system is necessary to test the vacuum chamber viewports, which i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physical Review Letters
سال: 2006
ISSN: 0031-9007,1079-7114
DOI: 10.1103/physrevlett.97.130801