Acetalization of hexanal with 2-ethyl hexanol catalyzed by solid acids
نویسندگان
چکیده
منابع مشابه
Dielectric and Thermodynamic Properties of 2, 3-Butanediol + 2-ethyl-1-hexanol Mixtures
Experimental results of dielectric investigations for binary mixtures of 2, 3-butanediol, 2, 3-BD, in2-ethyl-1-hexanol, 2EH, were reported for various mole fractions and temperatures (298.2-308.2) Kand they were used to calculate dielectric parameters such as Kirkwood correlation factor, excesspermittivity and Bruggeman parameter. These parameters were used to carry out temperaturedependent die...
متن کاملDielectric relaxation of 2-ethyl-1-hexanol around the glass transition by thermally stimulated depolarization currents.
We explore new routes for characterizing the Debye-like and α relaxation in 2-ethyl-1-hexanol (2E1H) monoalcohol by using low frequency dielectric techniques including thermally stimulated depolarization current (TSDC) techniques and isothermal depolarization current methods. In this way, we have improved the resolution of the overlapped processes making it possible the analysis of the data in ...
متن کاملdielectric and thermodynamic properties of 2, 3-butanediol + 2-ethyl-1-hexanol mixtures
experimental results of dielectric investigations for binary mixtures of 2, 3-butanediol, 2, 3-bd, in2-ethyl-1-hexanol, 2eh, were reported for various mole fractions and temperatures (298.2-308.2) kand they were used to calculate dielectric parameters such as kirkwood correlation factor, excesspermittivity and bruggeman parameter. these parameters were used to carry out temperaturedependent die...
متن کاملlactic acid extraction from aqueous solutions with 2-Ethyl-1-hexanol by using experimental liquid-liquid equilibrium data at T=298.2K and atmospheric pressure
Liquid-Liquid equilibrium data for the (water + Lactic acid + 2-ethy-1-hexanol) ternary system in T=298.2K and P=1atm were determined and tie- lines related to equilibrium data has been drawn in the phases diagram . The reliability of the experimental tie-line data for this system was as confirmed by using the Hand and Othmer –Tobias correlations. The tie-line data were correlated by means of t...
متن کامل2-Ethyl-1-hexanol in Indoor Air as a Possible Cause of Sick Building Symptoms
Department of Occupational and Environmental Health, Nagoya University Graduate School of Medicine, Nagoya City Public Health Research Institute, Department of Medical Technology, Nagoya University School of Health Sciences, Department of Environmental Dermatology, Nagoya University School of Medicine, Second Department of Internal Medicine, Nagoya University School of Medicine and Research Cen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Brazilian Chemical Society
سال: 2011
ISSN: 0103-5053
DOI: 10.1590/s0103-50532011000200023