Active vibration control of a three-dimensional flexible frame structure.
نویسندگان
چکیده
منابع مشابه
THREE SCHEMES FOR ACTIVE CONTROL OF THE PLANAR FRAME
Optimal locations of the actuators for frame active control are investigated in this article. The aim is to minimize the structural drifts by employing several actuators. By utilizing genetic algorithm, the appropriate locations of the actuators are determined. They should be placed in locations where they can minimize the maximum structural drift. To explore the capability of the proposed tech...
متن کاملActive vibration control of a three-stage tensegrity structure
This experimental study demonstrates the efficiency of simple control strategies to damp a 3-stage tensegrity tower structure. The tower is mounted on a moving support which is excited with a limited bandwidth random signal (filtered white noise) by a shaker. Our goal is to minimize the transmissibility between base acceleration and top plate acceleration using piezoelectric displacement actuat...
متن کاملActive Vibration Suppression of a Nonlinear Flexible Spacecraft
In this article, the issue of attitude control and active vibration suppression of a nonlinear flexible spacecraft is assessed through piezoelectric patches as actuator and sensors. Two controller loops are applied: the inner loop, to make the panel vibration damped through piezoelectric patches; and the outer loop, to perform spacecraft maneuver using the reaction wheel acting on the hub. An o...
متن کاملCoupled BE-FE Scheme for Three-Dimensional Dynamic Interaction of a Transversely Isotropic Half-Space with a Flexible Structure
The response of structures bonded to the surface of a transversely isotropic half-space (TIHS) under the effect of time-harmonic forces is investigated using a coupled FE-BE scheme. To achieve this end, a Finite Element program has been developed for frequency domain analysis of 3D structures, as the first step. The half-space underlying the structure is taken into consideration using a Boundar...
متن کاملVibration Control of Piezoelectric Flexible Structure Using Robust Control Methodology
Active vibration control of a smart flexible cantilever beam was studied by using mode theory and μ synthesis method. The actuator is piezoceramic patch, the sensor is strain gauge. The finite element method and experimental modal test was applied to obtain the dynamic model of the smart structure. Taking account into uncertainty of the external disturbance and measurement noise, and uncertaint...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C
سال: 1990
ISSN: 0387-5024,1884-8354
DOI: 10.1299/kikaic.56.649