Acute Outcomes of a Latest Generation Self-expandable, Intra-annular, Re-sheathable Transcatheter Heart Valve: The Portico System in 107 Consecutive Patients

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Repeat transcatheter aortic valve implantation using a latest generation balloon-expandable device for treatment of failing transcatheter heart valves

BACKGROUND Paravalvular leakage (PVL) is a known complication of transcatheter aortic valve implantation (TAVI) and is associated with poor outcome. Besides balloon-post-dilatation, valve-in-valve (ViV) procedures can be taken into consideration to control this complication. Herein we present initial experience with use of the latest generation balloon-expandable Edwards Sapien 3® (S3) transcat...

متن کامل

SOURCE 3: 1-year outcomes post-transcatheter aortic valve implantation using the latest generation of the balloon-expandable transcatheter heart valve

Aims Transcatheter aortic valve implantation (TAVI) has developed from a procedure for patients with aortic stenosis inoperable or high risk for surgery, into a treatment option even for intermediate risk elderly patients. This development has been facilitated by the clinical learning curve and constant improvements of transcatheter heart valves used. We present total 1-year results of SOURCE 3...

متن کامل

Outcomes After Transcatheter Aortic Valve Replacement Using a Novel Balloon-Expandable Transcatheter Heart Valve: A Single-Center Experience.

OBJECTIVES Evaluation of 30-day outcomes after transcatheter aortic valve replacement (TAVR) with the novel balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV) (Edwards Lifesciences, Irvine, California) emphasizing the updated Valve Academic Research Consortium (VARC-2) criteria. BACKGROUND Preliminary data on clinical performance with the S3 THV are promising. However, informati...

متن کامل

Transcatheter aortic valve replacement with the SAPIEN 3: a new balloon-expandable transcatheter heart valve.

OBJECTIVES The aim of this study was to demonstrate the first-in-human feasibility and short-term clinical outcomes with a new balloon-expandable transcatheter heart valve (THV). BACKGROUND The SAPIEN 3 (S3) THV incorporates a paravalvular sealing system, an active 3-dimensional coaxial positioning catheter, and is compatible with a 14-F expandable sheath. METHODS The S3 THV was implanted i...

متن کامل

the role of type-d personality, social support and self-compassion in prediction of health behaviors in coronary heart disease patients

نظر به اهمیت و تاثیر روزافزون عوامل روانی – اجتماعی در سلامت جسمی و تاثیر عوامل روان شناختی در بروز بیماریهای مختلف از جمله بیماریهای قلبی و عروقی این پژوهش با هدف کلی بررسی ارتباط تیپ شخصیتی d ، حمایت اجتماعی و خود دلسوزی در پیش بینی رفتارهای بهداشتی بیماران کرونر قلبی و تعیین تفاوت بین بیماران کرونر قلبی با و بدون جراحی و افراد سالم در این متغیرها و رفتارهای بهداشتی آنان، انجام گرفت. جامعه آ...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Thoracic and Cardiovascular Surgeon

سال: 2018

ISSN: 0171-6425,1439-1902

DOI: 10.1055/s-0038-1628047