Adaptive techniques in electrical impedance tomography reconstruction

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Applications of Electrical Impedance Tomography in Neurology

Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...

متن کامل

Adaptive mesh refinement techniques for electrical impedance tomography.

Adaptive mesh refinement techniques can be applied to increase the efficiency of electrical impedance tomography reconstruction algorithms by reducing computational and storage cost as well as providing problem-dependent solution structures. A self-adaptive refinement algorithm based on an a posteriori error estimate has been developed and its results are shown in comparison with uniform mesh r...

متن کامل

Temporal image reconstruction in electrical impedance tomography.

Electrical impedance tomography (EIT) calculates images of the body from body impedance measurements. While the spatial resolution of these images is relatively low, the temporal resolution of EIT data can be high. Most EIT reconstruction algorithms solve each data frame independently, although Kalman filter algorithms track the image changes across frames. This paper proposes a new approach wh...

متن کامل

Monotonicity-Based Shape Reconstruction in Electrical Impedance Tomography

Current-voltage measurements in electrical impedance tomography (EIT) can be partially ordered with respect to definiteness of the associated self-adjoint Neumann-to-Dirichlet operators. With this ordering, a pointwise larger conductivity leads to smaller current-voltage measurements, and smaller conductivities lead to larger measurements. We present a converse of this simple monotonicity relat...

متن کامل

Optimal imaging with adaptive mesh refinement in electrical impedance tomography.

In non-linear electrical impedance tomography the goodness of fit of the trial images is assessed by the well-established statistical chi2 criterion applied to the measured and predicted datasets. Further selection from the range of images that fit the data is effected by imposing an explicit constraint on the form of the image, such as the minimization of the image gradients. In particular, th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physiological Measurement

سال: 2014

ISSN: 0967-3334,1361-6579

DOI: 10.1088/0967-3334/35/6/1111