منابع مشابه

Determination of ultra-low level 129I in vegetation using pyrolysis for iodine separation and accelerator mass spectrometry measurements

Radioactive isotopes of iodine are themost common radiological toxins from nuclear accidents due to their high release and high enrichment in human thyroid. Among the radioactive isotopes, long-lived I can not only be used for the estimation of the radioactive risk of short-lived radioactive isotopes of iodine to humans and ecosystems, but also for the investigation of the biogeochemical cycle ...

متن کامل

Laser photodetachment electron spectrometry of Ga −

We report the first experimental determination of the electron affinity of gallium. The experiment was performed using the laser photodetachment electron spectrometry technique. Photoelectron kinetic energy spectra from Cu− and O− were used to calibrate the energy scale for the Ga− photoelectron energy spectra. The electron affinity was determined to be 0.43±0.03 eV. This measurement is compare...

متن کامل

Accelerator Mass Spectrometry at Vera

The Vienna Environmental Research Accelerator (VERA) is a dedicated facility for accelerator mass spectrometry (AMS), operated at the University of Vienna since 1996. The principle of AMS with VERA and the advantage of measuring long-lived radioisotopes by atom counting (AMS) rather than decay counting (ß decay) is described. A brief overview on AMS applications is also presented.

متن کامل

Improving tritium exposure reconstructions using accelerator mass spectrometry.

Direct measurement of tritium atoms by accelerator mass spectrometry (AMS) enables rapid low-activity tritium measurements from milligram-sized samples and permits greater ease of sample collection, faster throughput, and increased spatial and/or temporal resolution. Because existing methodologies for quantifying tritium have some significant limitations, the development of tritium AMS has allo...

متن کامل

Accelerator mass spectrometry (AMS) in plutonium analysis

The paper summarizes the results of the 240Pu/239Pu atomic ratio studies in atmospheric fallout samples collected in 1986 over Gdynia (Poland) as well as three Baltic fish species collected in 1997 using the accelerator mass spectrometry. A new generation of AMS has been developed during last years and this method is an efficient and good technique to measure long-lived radioisotopes in the env...