Advanced Control of Three-Phase Four-Wire Inverters using Feedback Linearization under Unbalanced and Nonlinear Load Conditions
نویسندگان
چکیده
منابع مشابه
Hysteresis Control for Shunt Active Power Filter under Unbalanced Three-Phase Load Conditions
This paper focuses on a four-wire shunt active power filter (APF) control scheme proposed to improve the performance of the APF. This filter is used to compensate harmonic distortion in three-phase four-wire systems. Several harmonic suppression techniques have been widely proposed and applied to minimize harmonic effects. The proposed control scheme can compensate harmonics and reactive power ...
متن کاملImproving the performance of UPQC under unbalanced and distortional load conditions: A new control method
This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...
متن کاملAdaptive Speed Control of Three-Phase Induction Servo-drives Based on Feedback Linearization Theory
In this paper, based on feedback linearization control method and using a special PI (propotational integrator) regulator (IP) in combination with a feed-forward controller, a three-phase induction servo-drive is speed controlled. First, an observer is employed to estimate the rotor d and q axis flux components. Then, two input-output state variables are introduced to control the dynamics of to...
متن کاملAdaptive Speed Control of Three-Phase Induction Servo-drives Based on Feedback Linearization Theory
In this paper, based on feedback linearization control method and using a special PI (propotational integrator) regulator (IP) in combination with a feed-forward controller, a three-phase induction servo-drive is speed controlled. First, an observer is employed to estimate the rotor d and q axis flux components. Then, two input-output state variables are introduced to control the dynamics of to...
متن کاملA Three Phase Four Wire Shunt Active Power Filter Control Algorithm under Unbalanced and Distorted Supply Voltage
In this paper a control algorithm is validated with simulation studies in MAT environment and experimental studies are performed in to validate the proposed control algorithm. The projected algorithm to compensate the nonlinear and loads in three phase four wire distribution system using shunt active power filter. In this algorithm a positive sequence extraction of the supply voltage and the th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Transactions of the Korean Institute of Power Electronics
سال: 2013
ISSN: 1229-2214
DOI: 10.6113/tkpe.2013.18.4.333