advligorts: The Advanced LIGO real-time digital control and data acquisition system
نویسندگان
چکیده
The Advanced LIGO detectors are sophisticated opto-mechanical devices. At the core of their operation is feedback control. project developed a custom digital control and data acquisition system to handle unique needs this new breed astronomical detector. advligorts software component system. This highly modular extensible has enabled unprecedented performance instruments, been vital in direct detection gravitational waves.
منابع مشابه
The Ligo Suspended Optic Digital Control System
The original LIGO suspension control system [1] used analog circuitry to implement the closed loop damping required for local control of each of the suspended optics. As installation and commissioning activities have progressed, it has become apparent that these controls do not provide the performance and flexibility that will be required for operation of the interferometers. Recent development...
متن کاملReal Time Data Acquisition and Control
This paper presents a laboratory environment for the development of real time data acquisition and control on the IBM-PC platform. The laboratory station involves the integration of low-cost computer technology with powerful software components which empower the student to efficiently and effectively construct real time systems. The software base integrates an editor, a spreadsheet, and a real ...
متن کاملAn Overview of the LIGO Control and Data Acquisition Systems{*}
∗ Work supported by the National Science Foundation under Grant PHY-920038. Abstract Interferometric gravitational wave antennas are based on Michelson interferometers whose sensitivity to small differential length changes (for LIGO it is 1 part in 10) has been enhanced by adding multiple coupled optical resonators. These antennas are used to verify the theory of relativity by detecting gravita...
متن کاملReal Time Temperature Control System Using PID Controller and Supervisory Control and Data Acquisition System (SCADA)
Well designed conventional PID controllers using Ziegler-Nichols method are having large overshoot and settling time. Significant research work has been carried out to improve the performance of closed loop response with PID controller so that it can be used for real time temperature control system using SCADA(HC900 Honeywell controller). Also performance of PID controller is investigated for d...
متن کاملReal-time data acquisition and control system for the measurement of motor and neural data.
This paper outlines a powerful, yet flexible real-time data acquisition and control system for use in the triggering and measurement of both analog and digital events. Built using the LabVIEW development architecture (version 7.1) and freely available, this system provides precisely timed auditory and visual stimuli to a subject while recording analog data and timestamps of neural activity retr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: SoftwareX
سال: 2021
ISSN: ['2352-7110']
DOI: https://doi.org/10.1016/j.softx.2020.100619