The optimal age-based replacement policy for systems subject to shocks
In this article, two different systems subject to shocks occurring based on a non-homogeneous Poisson process (NHPP) are analyzed. Type –I system is consisted of a single unit and type –II system is consisted of two parallel units in which both units operate identically and simultaneously. In type –I system occurrence of a shock causes system stopping and consequently will be received minimal r...
متن کاملA multi-criteria optimal replacement policy for a system subject to shocks
A system is subject to shocks that arrive according to a non-homogeneous Poisson process. As these shocks occur, the system experiences one of two types of failures: a type-I failure (minor), rectified by a minimal repair; or a type-II failure (catastrophic) that calls for a replacement. In this study, we consider a multi-criteria replacement policy based on system age, nature of failure, and e...
متن کاملAGE REPLACEMENT POLICY IN UNCERTAIN ENVIRONMENT
Age replacement policy is concerned with finding an optional time tominimize the cost, at which time the unit is replaced even if itdoes not fail. So far, age replacement policy involving random agehas been proposed. This paper will assume the age of the unit is anuncertain variable, and find the optimal time to replace the unit.
متن کاملCost- Benefit Analysis of a Single-unit System Subject to Random Shocks
The purpose of the present study is to carry out cost-benefit analysis of a single-unit system subject to random shocks. The operative unit may be affected by the impact of random shocks with some probabilities. The unit may fail completely due to the reasons other than shocks. There is a single server who visits the system immediately. The maintenance of the unit is carried out by the server i...
متن کاملOptimal Opportunistic Maintenance Policy for a Two-Unit System
This paper presents a maintenance policy for a system consisting of two units. Unit 1 is gradually deteriorating and is subject to soft failure. Unit 2 has a general lifetime distribution and is subject to hard failure. Condition of unit 1 of the system is monitored periodically and it is considered as failed when its deterioration level reaches or exceeds a critical level N . At the failure ti...