Air Density Measuring Device - Innovative Design, Calibration and Exemplary Results
نویسندگان
چکیده
منابع مشابه
Calibration of Laser Beam Direction for Inner Diameter Measuring Device
The laser triangulation method is one of the most advanced methods for large inner diameter measurement. Our research group proposed a kind of inner diameter measuring device that is principally composed of three laser displacement sensors known to be fixed in the same plane measurement position. It is necessary to calibrate the direction of the laser beams that are emitted by laser displacemen...
متن کاملDesign and Calibration of a New 6 DOF Haptic Device
For many applications such as tele-operational robots and interactions with virtual environments, it is better to have performance with force feedback than without. Haptic devices are force reflecting interfaces. They can also track human hand positions simultaneously. A new 6 DOF (degree-of-freedom) haptic device was designed and calibrated in this study. It mainly contains a double parallel l...
متن کاملThe T-Sonde, a low level air temperature measuring device.
A system to obtahi the detailed temperature profiles from the ground surface to heights of 1500-2000 ni. has been This economical system employs modified radiosondes and less complex receiving equipment than used A simplified approach for obtaining heights by means of a modified baroswitch The temperature measuring system has performed successfully for two years with reljable developed. at stan...
متن کاملICARE Radon Calibration Device
An aerodynamic calibration device called ICARE is briefly described. ICARE is currently being used at the Nuclear Research Center of Saclay in France for the certification of instruments employed in measurement of artificial radioactive particulate airborne contamination. ICARE is essentially a blower. Aerosols calibrated in size and labelled with 137Cs or 239Pu are injected in the mainstream o...
متن کاملEffect of Air Density on Cyclone Performance and System Design
1D3D and 2D2D cyclones were tested at Amarillo, Texas, to evaluate the effect of air density on cyclone performance. Both airflow rate and cyclone inlet velocity change with the change in air density. Two sets of inlet design velocities determined by the different air densities were used for the tests: one set based on the actual airflow, and the other set based on standard airflow. Experimenta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Instrumentation Mesure Métrologie
سال: 2020
ISSN: 1631-4670,2269-8485
DOI: 10.18280/i2m.190602