Air side performance of tube bank of an evaporator in a window air-conditioner by CFD simulation with different circular tubes with uniform transverse pitch variation

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Window Air Conditioner with Orthodox Refrigerants

The system design of window air conditioner does not evolve in one day. Due to the continous efforts are taken by the refrigeration and air conditionging professionals, successful and economic models of window air conditioners are currently used. This paper states about the development of window air conditioner with phase change material and water as refrigerants. Developed air conditioner was ...

متن کامل

Experimental Performance of Window Air Conditioner Using Alternative Refrigerants with Different Configurations of Capillary Tube A Review

This review paper presents the work of various researches on the performance of capillary tube ,used in air conditioners with various refrigerants. Research carried out by different authors uses different type of capillary tubes (straight, twisted, coiled) in different length and diameter. they determined various parameters like coefficient of performance (COP),cooling capacity, energy efficien...

متن کامل

Design and Experimentation of Roll Bond Evaporator for Room Air Conditioner with R-22 as Refrigerant

The world is looking towards producing products which consume less power without compromising on quality of life. The increase in use of refrigeration and air conditioning appliances are contributing to global warming. The world wide temperatures are shooting up at an increasing rate. This paper presents a design of roll bond evaporator as the heat exchanger to provide cooling in room air condi...

متن کامل

Effects of Non-Uniform Refrigerant and Air Flow Distributions on Finned- Tube Evaporator Performance

An experimental investigation was implemented to determine the capacity degradation due to non-uniform refrigerant and air flow distributions, and to assess the potential to recover the lost capacity via controlling refrigerant distribution between individual refrigerant circuits. The tests were performed on a three-circuit, threedepth-row, finned-tube evaporator. Refrigerant inlet quality, exi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Thermofluids

سال: 2020

ISSN: 2666-2027

DOI: 10.1016/j.ijft.2020.100028