Alias-free interpolation technique for pulsed Doppler signal.
نویسندگان
چکیده
منابع مشابه
Towards Alias-Free Pointers
This paper argues that pointer-induced aliasing can be avoided in many cases by means of a concept of unique pointer. The use of such pointers is expected to fortify the concept of encapsulation, to make systems easier to reason about, to provide better control over the interaction between threads, and to make storage management safer and more ef-cient. We show that unique pointers can be imple...
متن کاملAlias-Free Shadow Maps
In this paper we abandon the regular structure of shadow maps. Instead, we transform the visible pixels P(x,y,z) from screen space to the image plane of a light source P′(x′,y′,z′). The (x′,y′) are then used as sampling points when the geometry is rasterized into the shadow map. This eliminates the resolution issues that have plagued shadow maps for decades, e.g., jagged shadow boundaries. Inco...
متن کاملNoninvasive evaluation of pulmonary hypertension by a pulsed Doppler technique.
We used a pulsed Doppler technique to examine the flow velocity pattern in the right ventricular outflow tract in 33 adults. In the patients with normal pulmonary artery pressure (mean pressure less than 20 mm Hg, 16 patients), ejection flow reached a peak level at midsystole (137 +/- 24 msec, mean +/- SD), producing a domelike contour of the flow velocity pattern during systole. In contrast, t...
متن کاملPulmonary regurgitation studied with the ultrasonic pulsed Doppler technique.
Sixty patients with pulmonary regurgitation were studied by the pulsed Doppler technique combined with two-dimensional and M-mode echocardiography. Patients with pulmonary regurgitation had abnormal Doppler signals just below the pulmonic valve in the right ventricular outflow tract in diastole on the two-dimensional image. These signals were considered to indicate the regurgitant flow. There a...
متن کاملECHOCARDIOGRAPHV - DOPPLER Noninvasive evaluation of pulmonary hypertension by a pulsed Doppler technique
We used a pulsed Doppler technique to examine the flow velocity pattern in the right ventricular outflow tract in 33 adults. In the patients with normal pulmonary artery pressure (mean pressure < 20 mm Hg, 16 patients), ejection flow reached a peak level at midsystole (137 + 24 msec, mean + SD), producing a domelike contour of the flow velocity pattern during systole. In contrast, the flow velo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Acoustical Society of Japan (E)
سال: 1993
ISSN: 0388-2861,2185-3509
DOI: 10.1250/ast.14.259