AlphaCor artificial cornea: clinical outcome
نویسندگان
چکیده
منابع مشابه
Cornea procurement from very old donors: post organ culture cornea outcome and recipient graft outcome.
AIM To study the suitability of corneas from very old donors for graft after banking and their clinical and endothelial outcomes in recipients. METHODS 419 corneas stored in organ culture were divided into group 1, donors under 85 years (330 corneas) and group 2, "very old" donors aged 85 years and over (89 corneas). Endothelial cell density (ECD) before and after organ culture, discard rate ...
متن کامل4117 A novel biointegrable artificial cornea
m Our previous studies demonstrated functional differentiatedcells and collagen synthesis in the pores of an ePrFE implant. This study quantifies and identities collagen types synthesized in this polymer. Methods: Rabbit eyes were implanted with a 6mm diameter disc of an ePTFE disc (Impra@,) (0.2”” thick, SO/r” pore :size with a mean porosity of 88*4% and the channels were perpendicular to the ...
متن کاملClinical Trials: Cornea
These characteristics have led to attempts to keep the cornea disease free and clear as far as possible by means of a series of landmark studies which include the control of infections trials and trials related to corneal transplants for maintaining the clear optical media. Following is a brief synopsis of the various studies related to cornea which have showed us the way to manage these ailments.
متن کاملOutcome Measures for Artificial Pancreas Clinical Trials: A Consensus Report
Research on and commercial development of the artificial pancreas (AP) continue to progress rapidly, and the AP promises to become a part of clinical care. In this report, members of the JDRF Artificial Pancreas Project Consortium in collaboration with the wider AP community 1) advocate for the use of continuous glucose monitoring glucose metrics as outcome measures in AP trials, in addition to...
متن کاملA second generation of artificial cornea (Biokpro II).
The properties of a new second-generation colonizable artificial cornea were evaluated in humans. The prosthesis consisted of a peripheral rim of a translucent microporous fluorocarbon polymer (expanded polytetrafluoroethylene) fused with the polymer of the central optic. The optic was made of medical-grade polydimethylsiloxane coated with polyvinylpyrrolidone. Its refractive power was 42.2 dio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Eye
سال: 2011
ISSN: 0950-222X,1476-5454
DOI: 10.1038/eye.2011.122