Alterations in carotid arterial velocity-time profile produced by the Blalock-Taussig shunt.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Alterations in carotid arterial velocity-time profile produced by the Blalock-Taussig shunt.

13. Dyer AR, Stamler J, Shekelle RB, Schoenberger J: The relationship of education to blood pressure. Circulation 54: 987, 1976 14. Becker M (ed): The health belief model and personal health behavior. Health Educ Monogr 2: 236, 1974 15. Baric L: Recognition of the "at risk" role: a means to influence health behavior. Int J Health Educ 12: 24, 1969 16. American Heart Association Long Range Plan,...

متن کامل

The Blalock and Taussig Shunt Revisited

The systemic to pulmonary artery shunts are done as palliative procedures for cyanotic congenital heart diseases ranging from simple tetralogy of Fallots (TOFs)/pulmonary atresia (PA) to complex univentricular hearts. They allow growth of pulmonary arteries and maintain regulated blood flow to the lungs till a proper age and body weight suitable for definitive corrective repair is reached. We h...

متن کامل

False aneurysm following modified Blalock-Taussig shunt.

A nine month old infant with life threatening tracheal compression due to a Blalock-Taussig shunt aneurysm is described. Successful surgical management is discussed.

متن کامل

Pseudoaneurysm following modified Blalock Taussig shunt.

The modified Blalock-Taussig (BT) shunt is a common palliative procedure for congenital cyanotic heart disease (CHD) with diminished pulmonary blood flow(1). In developing countries, definitive surgery usually gets delayed due to limited resources and expertise(2). Children with cyanotic CHD and BT shunt often present to the pediatrician resulting in some of the complications of BT shunt being ...

متن کامل

Blalock - Taussig shunt . modified ( polytetrafluoroethylene ) Balloon dilatation of a stenosed

A 17 month old girl with tricuspid atresia, ventricular septal defect, subvalvar and valvar pulmonary stenosis, and increasing cyanosis had angiographic evidence ofproximal stenosis of a right modified (5 mm diameter) Blalock-Taussig shunt. She underwent palliative balloon angioplasty with a 6 mm Schneider balloon catheter. Successful dilatation was achieved without complication. Four months la...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Circulation

سال: 1981

ISSN: 0009-7322,1524-4539

DOI: 10.1161/01.cir.63.5.1115