Alveolar sampling and fast kinetics of tetrachloroethene in man. I. Alveolar sampling.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Alveolar sampling and fast kinetics of tetrachloroethene in man. I. Alveolar sampling.

Human subjects were exposed to tetrachloroethene (perchloroethylene, PER). The duration of exposure ranged from one to 60 minutes and the concentration of PER in inhaled air ranged from 0.02 to 0.40 mmol/m3. Alveolar air was sampled after several residence times (t*) in the lung. Both during and after exposure, the concentration of PER in alveolar air (C Alv) as a function of the residence time...

متن کامل

Application of adaptive sampling in fishery part 1: Adaptive cluster sampling and its strip designs

Abstract:  The precision of conventional sampling designs is not usually satisfactory for estimating parameters of clump and rare populations. Many of fish species live in school and disperse all over a vast area like a sea so that they are rare compare to their habitats. Theory of a class of sampling designs called adaptive sampling designs has rapidly grown during last decade which solv...

متن کامل

Application of adaptive sampling in fishery part 1: Adaptive cluster sampling and its strip designs

Abstract:  The precision of conventional sampling designs is not usually satisfactory for estimating parameters of clump and rare populations. Many of fish species live in school and disperse all over a vast area like a sea so that they are rare compare to their habitats. Theory of a class of sampling designs called adaptive sampling designs has rapidly grown during last decade which solved the...

متن کامل

CO(2)-controlled sampling of alveolar gas in mechanically ventilated patients.

A newly designed gas-sampling device using end-tidal CO(2) to separate dead space gas from alveolar gas was evaluated in 12 mechanically ventilated patients. For that purpose, CO(2)-controlled sampling was compared with mixed expiratory sampling. Alveolar sampling valves were easily controlled via CO(2) concentration. Concentrations of four volatile substances were determined in the expired and...

متن کامل

Continuous Fast Fourier Sampling

Fourier sampling algorithms exploit the spectral sparsity of a signal to reconstruct it quickly from a small number of samples. In these algorithms, the sampling rate is subNyquist and the time to reconstruct the dominate frequencies depends on the type of algorithm—some scale with the number of tones found and others with the length of the signal. The Ann Arbor Fast Fourier Transform (AAFFT) s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Occupational and Environmental Medicine

سال: 1986

ISSN: 1351-0711

DOI: 10.1136/oem.43.12.814