Amperometric Gas Sensor Using Gas Diffusion Membrane Consisting of Carbon Powder and Fluorocarbon
نویسندگان
چکیده
منابع مشابه
hazard evaluation of gas condensate stabilization and dehydration unit of parsian gas refinery using hazop procedures
شناسایی مخاطرات در واحد 400 پالایشگاه گاز پارسیان. در این پروزه با بکارگیری از تکنیک hazop به شناسا یی مخاطرات ، انحرافات ممکن و در صورت لزوم ارایه راهکارهای مناسب جهت افزایش ایمنی فرا یند پرداخته میگردد. شرایط عملیاتی مخاطره آمیز نظیر فشار و دمای بالا و وجود ترکیبات مختلف سمی و قابل انفجار در واحدهای پالایش گاز، ضرورت توجه به موارد ایمنی در این چنین واحدهایی را مشخص می سازد. مطالعه hazop یک ر...
Mathematical Modeling of Gas Separation Process with Flat Carbon Membrane
Carbon molecular sieve membranes (CMSMs) have been considered as very promising candidates for gas separation, in terms of separation properties as well as thermal and chemical stability. Due to the numerous advantages and wide applications of carbon membranes, their application for gas separation is of special importance. Because of the importance of carbon membranes and a large number of stud...
متن کاملSingle-Walled Carbon Nanotube Network Gas Sensor
Gas sensors are generally defined as devices to detect or measure concentration of (bio-) chemicals in gaseous state. The demands of highly sensitive gas sensors for industry, environmental monitoring, safety, biomedicine, and pharmaceutics have provoked the intensive research interests in micro-electromechanical systems (MEMS) and nanotechnology. The nanotechnology in conjunction with MEMS has...
متن کاملAn electrothermal carbon nanotube gas sensor.
We show both gas pressure and species sensing capabilities based on the electrothermal effect of a multiwalled carbon nanotube (MWCNT). Upon exposure to gaseous environments, the resistance of a heated MWCNT is found to change following the conductive heat-transfer variances of gas molecules. To realize this mechanism, a suspended MWCNT is constructed by synthesis and assembly in localized chem...
متن کاملBromide Determination in Pharmaceutical Preparations Using Indirect Gas-Diffusion Flow Injection Method with Amperometric Detector
The indirect gas-diffusion flow injection method (FI) was modified, optimized and successfully applied to bromide determination in various samples such as active substances, drugs, organic substances and water samples. The method is based on the oxidation of bromide to bromine in acidic medium, which diffuses through PTFe membrane into the acceptor flow that carried bromine to the amperometric ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Sensors and Micromachines
سال: 2004
ISSN: 1341-8939,1347-5525
DOI: 10.1541/ieejsmas.124.402