Amperometric Glucose Sensor Fabricated Using Electroless Processes.
نویسندگان
چکیده
منابع مشابه
Fabrication of a Flexible Amperometric Glucose Sensor Using Additive Processes.
This study details the use of printing and other additive processes to fabricate a novel amperometric glucose sensor. The sensor was fabricated using a Au coated 12.7 μm thick polyimide substrate as a starting material, where micro-contact printing, electrochemical plating, chloridization, electrohydrodynamic jet (e-jet) printing, and spin coating were used to pattern, deposit, chloridize, prin...
متن کاملOptimizing Electroless Nickel Pretreatment Processes
The pretreatment of the substrate, prior to Electroless Nickel (EN) plating, plays an important role in the corrosion protection provided by the EN deposit. Many factors in the pretreatment process can affect the corrosion resistance of the EN deposit. The details of mechanical treatment, chemical/elecuo polishing, acid activation, and pre-processing procedure (such as nickel strike) are among ...
متن کاملAmperometric glucose sensor for real time extracellular glucose monitoring in microfluidic device
We have combined a microfluidic network and developed a miniature glucose sensor to measure glucose consumption of single cardiomyocytes in a confined extracellular space. The thin film glucose sensor was integrated into a 360 picoliter extracellular space. We used Pt thin film electrodes (20x100 μm) as a counter electrode, and a needle type reference electrode (0.45 mm diam) placed in the cell...
متن کاملA New Approach to Glucose Monitoring Using a Non-Invasive Ocular Amperometric Electro-Chemical Glucose Sensor for the Diabetics
A non-invasive method of monitoring blood glucose would present major advantages over existing methods, since the problems listed in this study are specific to invasive testing procedures. Our group will attempt to develop a new technology for the noninvasive monitoring of tear glucose levels, potentially blood glucose monitoring, using a disposable contact lens embedded with glucose sensing me...
متن کاملPlanar Amperometric Glucose Sensor Based on Glucose Oxidase Immobilized by Chitosan Film on Prussian Blue Layer
A planar amperometric glucose microsensor based on glucose oxidase immobilized by chitosan film on Prussian Blue layer has been developed. The experimental results show that the optimum detection potential is 50 mV (versus Ag/AgCl) and the optimum pH is 6.5. Under the selective conditions the sensor exhibits excellent sensitivity of 98 nA/M and a linear range of 0.1-6.0 mM. The apparent Michane...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Surface Finishing Society of Japan
سال: 1998
ISSN: 0915-1869,1884-3409
DOI: 10.4139/sfj.49.894